GADSDEN, AL —
OSHA Inspection: RAINBOW CULTURED MARBLE
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of RAINBOW CULTURED MARBLE in 1800 US HIGHWAY 278 EAST, GADSDEN, AL 35903 (NAICS 326191). OSHA activity number 335864195.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RAINBOW CULTURED MARBLE
- Site address
- 1800 US HIGHWAY 278 EAST
- City
- GADSDEN
- State
- AL
- ZIP
- 35903
- Mailing
- P.O. BOX 2126, GADSDEN, AL 35903
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326191
- Employees
- 4
- Ownership type
- A
Citations
14 citations on file for this inspection.
1910.22 A01
- Issued
- Nov 19, 2012
- Abate by
- Jan 23, 2013
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, store rooms or service rooms were not kept clean and orderly or in a sanitary condition: (a) On or about August 20, 2012 - Facility, Blending Area, cultured marble powder had accumulated on the floor and tables creating a dust inhalation hazard.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1910.107 G02
- Issued
- Nov 19, 2012
- Abate by
- Jan 23, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary: (a) On or about August 20, 2012 - Facility, Spraying Area, resin had accumulated on the floors and tables creating fire and tripping hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.106 E02 IV D
- Issued
- Nov 19, 2012
- Abate by
- Dec 8, 2012
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.106(e)(2)(iv)(d): Flammable or combustible liquids were not drawn from or transferred into vessels, containers, or portable tanks within a building only through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container or portable tanks by gravity through an approved self-closing valve: (a) On or about August 20, 2012 - Facility, Blending Area, one 55-gallon drum containing acetone was not equipped with a self-closing valve.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1910.107 G05
- Issued
- Nov 19, 2012
- Abate by
- Jan 23, 2013
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.107(g)(5): The use of solvents for cleaning operations was not restricted to those having flashpoints not less than 100 F: (a) On or about August 20, 2012 - Facility, Blending Area, acetone was used to clean spray nozzles and a bucket that contained a mixture of styrene and methyl ethyl ketone.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1910.107 G07
- Issued
- Nov 19, 2012
- Abate by
- Nov 30, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(g)(7): "No smoking" signs in large letters on contrasting color background were not conspicuously posted at all spraying areas and paint storage rooms: (a) On or about August 20, 2012 - Facility, Spraying Area, "No Smoking" signs were not posed in spraying areas.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.133 A01
- Issued
- Nov 19, 2012
- Abate by
- Nov 30, 2012
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: (a) On or about August 20, 2012 - Facility, Blending, Grinding, and Spraying Operations, an employee who prepared the blend to be poured on molds, sprayed resin and gel coat, and performed grinding was not wearing eye or face protection.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1910.157 E02
- Issued
- Nov 19, 2012
- Abate by
- Dec 23, 2012
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: (a) On or about August 20, 2012 - Facility, portable fire extinguishers, ABC type, were not visually inspected every month.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1910.157 G02
- Issued
- Nov 19, 2012
- Abate by
- Dec 23, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: (a) On or about August 20, 2012 - Facility, employees who were expected by the employer to use portable fire extinguishers during small fires were not provided with training about the use of the equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Nov 19, 2012
- Abate by
- Jan 23, 2013
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for the fixed wiring of a structure: (a) On or about August 20, 2012 - Facility, Grinding Area, extension cords were used to connect grinders and buffing machines. (b) On or about August 20, 2012 - Facility, Mold Pouring Area, an extension cord was used to power a fan.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1910.1200 E01
- Issued
- Nov 19, 2012
- Abate by
- Jan 23, 2013
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) On or about August 20, 2012 - Facility, a written hazard communication program was not developed and implemented for employees that were exposed to hazardous chemicals such as, but not limited to, calcium carbonate, crystalline silica (Marblend), styrene monomer, Methyl Ethyl Ketone, and Methyl Ethyl Ketone Peroxide (Syrgis Norox ).
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1910.1200 H01
- Issued
- Nov 19, 2012
- Abate by
- Jan 23, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): The employer did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees had not previously been trained about was introduced into their work area: (a) On or about August 20, 2012 - Facility, employees who were exposed to hazardous chemicals such as calcium carbonate, crystalline silica, styrene monomer, methyl ethyl ketone, acetone, and methyl ethyl ketone peroxide were not informed and trained about the hazards associated with these chemicals.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.37 B02
- Issued
- Nov 19, 2012
- Abate by
- Nov 30, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": (a) On or about August 20, 2012 - Facility, four exit doors were not provided with exit signs.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 D01 I
- Issued
- Nov 19, 2012
- Abate by
- Dec 8, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(d)(1)(i): The employer did not select and provide appropriate respiratory protection based on the respiratory hazard(s) to which the worker(s) was exposed and workplace and user factors that affect respirator performance and reliability: (a) On or about August 20, 2012 - Facility, an employee who was exposed to mist and vapors of styrene (resin, gel coat), and methyl ethyl ketone peroxide during spraying operations was wearing a particulate mask.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 D01 II
- Issued
- Nov 19, 2012
- Abate by
- Dec 8, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(d)(1)(ii): The employer did not select a NIOSH-certified respirator for use in compliance with the conditions of its certification: (a) On or about August 20, 2012 - Facility, an employee who was exposed to styrene, methyl ethyl ketone peroxide, marble powder, and acetone during blending, spraying, and cleaning operations was wearing a dust mask not certified by NIOSH.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Rainbow Cultured Marble
View Rainbow Cultured Marble's full OSHA safety record →
More inspections in this industry (NAICS 326191)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335864195.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.