TWO RIVERS, WI —
OSHA Inspection: VALENTIN ALVARADO
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of VALENTIN ALVARADO in RIVER HOUSE APT 1523 16TH ST., TWO RIVERS, WI 54241 (NAICS 238160). OSHA activity number 335869418.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VALENTIN ALVARADO
- Site address
- RIVER HOUSE APT 1523 16TH ST.
- City
- TWO RIVERS
- State
- WI
- ZIP
- 54241
- Mailing
- 2450 HONEYLOU CT #202, APPLETON, WI 54915
What kind of inspection was it?
- Inspection type
- Programmed Related (J)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 10
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.102 A01
- Issued
- Sep 19, 2012
- Abate by
- Oct 11, 2012
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. Employees performing reroofing work were not wearing or provided with safety glasses.
Recent events (1)
- — Z (S) $2000
1926.501 B13
- Issued
- Sep 19, 2012
- Abate by
- Oct 11, 2012
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.501(b)(13): Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b) Five employees were reroofing a three story apartment building without any form of fall protection.
Recent events (1)
- — Z (S) $2800
1926.1053 B01
- Issued
- Sep 19, 2012
- Abate by
- Sep 26, 2012
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: The ladder used to access the roof surface did not extend three feet above the eave edge.
Recent events (1)
- — Z (S) $2000
1926.152 F01
- Issued
- Sep 19, 2012
- Abate by
- Sep 26, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.152(f)(1): Flammable liquids were not kept in closed containers when not actually in use: The five gallon gas can used to fuel the air compressor did not have a cap to seal the can.