Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BARE METALS, LLC

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of BARE METALS, LLC in 56 JARRELL ROAD, GREENVILLE, GA 30222 (NAICS 423930). OSHA activity number 335872206.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bare Metals, LLC — free Get an email when a new federal OSHA severe-injury report for Bare Metals, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
BARE METALS, LLC
Site address
56 JARRELL ROAD
City
GREENVILLE
State
GA
ZIP
30222
Mailing
56 JARRELL ROAD, GREENVILLE, GA 30222
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
20
Ownership type
A

3 citations on file for this inspection.

1910.110 E04 III

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 19, 2012
Abate by
Nov 9, 2012
Penalty
Initial $1,320 · Current $528 Reduced
29 CFR 1910.110(e)(4)(iii): Permanent and removable fuel containers were not securely mounted to prevent jarring loose, slipping, or rotating:    a) Warehouse Area - The holding latch used to secure the LP gas cylinder on the Toyota forklift truck, was broken, leaving the cylinder unsecured.  Employee(s) were exposed to an explosion hazard and/or struck-by hazard.
Recent events (2)
  • — I (S) $528
  • — Z (S) $1320

1910.132 A

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 19, 2012
Abate by
Nov 9, 2012
Penalty
Initial $1,320 · Current $528 Reduced
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:    a) Warehouse Area - Forklift was not equipped with proper personal protective equipment such as: a seat belt (operating restraint system). Employees were exposed to a struck-by hazard.
Recent events (2)
  • — I (S) $528
  • — Z (S) $1320

1910.303 G01

Other-than-serious 1 instance 1 exposed
Issued
Oct 19, 2012
Abate by
Nov 9, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    a) Warehouse Area - Equipment such as computer database was stored in front of the 240 volts electrical panel box creating insufficient working space for authorized personnel who were required to perform service or maintenance on the equipment.  Employees were exposed to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Bare Metals, LLC's full OSHA safety record →