BALTIMORE, MD —
OSHA Inspection: BALTERM
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BALTERM in SOUTH LOCUST POINT, 2001 MCCOMAS ST, BALTIMORE, MD 21230 (NAICS 493190). OSHA activity number 335875415.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BALTERM
- Site address
- SOUTH LOCUST POINT, 2001 MCCOMAS ST
- City
- BALTIMORE
- State
- MD
- ZIP
- 21230
- Mailing
- SOUTH LOCUST POINT, 2001 MCCOMAS ST, BALTIMORE, MD 21230
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493190
- Employees
- 83
- Ownership type
- A
Citations
1 citation on file for this inspection.
1917.43 C05
- Issued
- Nov 28, 2012
- Abate by
- Dec 18, 2012
- Penalty
- Initial $2,100 · Current $2,100
General-duty citation text
29 CFR 1917.43(c)(5): Powered industrial trucks shall be maintained in safe working order. Safety devices shall not be removed or made inoperative except as otherwise provided in this section. Trucks with a fuel system leak or any other safety defect shall not be operated. a) An employee was observed operating a powered industrial truck with an inoperable back-up alarm. The powered industrial truck is an Eagle TE-330M, Serial number: S-L1-23752. b) An employee was observed operating a powered industrial truck with an inoperable back-up alarm and horn. The powered industrial truck is a Hyster S155XL2, Serial number: C024V02666D. c) An employee was observed operating a powered industrial truck with an inoperable back-up alarm. The powered industrial truck is a Yale GC155CANGBE098, Serial number: B879V01523B. d) An employee was observed operating a powered industrial truck with degraded tires. The powered industrial truck is a Yale GLP120VXNGGE084, Serial number: F813V03377F.
Recent events (2)
- — I (O) $2100
- — Z (S) $2100