OSHA Inspection: BONEL BUILDERS, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BONEL BUILDERS, LLC in 3450 TOWNSEND BLVD, JACKSONVILLE, FL 32277 (NAICS 238160). OSHA activity number 335875431.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bonel Builders, LLC for free Get an email when a new federal OSHA severe-injury report for Bonel Builders, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
BONEL BUILDERS, LLC
Site address
3450 TOWNSEND BLVD
City
JACKSONVILLE
State
FL
ZIP
32277
Mailing
P.O. BOX 272379, TAMPA, FL 33688
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
10
Ownership type
A

2 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 7 exposed
Issued
Sep 10, 2012
Penalty
Initial $918 · Current $500 Reduced
29 CFR 1926.100(a):   Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:    a. On or about July 20, 2012, on the ground level, employees were not wearing hard hats while working below employees on the roof, exposing themselves to the hazard of being struck by falling debris.
Recent events (2)
  • · I (S) $500
  • · Z (S) $918

1926.1053 B01

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 10, 2012
Penalty
Initial $918 · Current $500 Reduced
29 CFR 1926.1053(b)(1):   When portable ladders are used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support:      a. On or about July 20, 2012, the ladder used to access the roof did not extend three feet above the landing, exposing employees to a 16 feet fall hazard.
Recent events (2)
  • · I (S) $500
  • · Z (S) $918

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335875431.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.