SEGUIN, TX —
OSHA Inspection: CAVCO INDUSTRIES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CAVCO INDUSTRIES, INC. in 2301 N. HIGHWAY 46, SEGUIN, TX 78155 (NAICS 321991). OSHA activity number 335883799.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CAVCO INDUSTRIES, INC.
- Site address
- 2301 N. HIGHWAY 46
- City
- SEGUIN
- State
- TX
- ZIP
- 78155
- Mailing
- 2301 N. HIGHWAY 46, SEGUIN, TX 78155
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321991
- Employees
- 500
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.23 C01
- Issued
- Sep 27, 2012
- Abate by
- Sep 28, 2012
- Penalty
- Initial $7,000 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. The railing shall be provided with a toe board wherever, beneath the open sides. On or about August 22, 2012, employees were installing the roof decking and asphalt shingles to the roof of a mobile home being built while working near the edges of the building and not provided fall protection, exposing employees to a fall hazard of up to approximately15 feet onto a concrete floor. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that every open-sided floor or platform 4 feet or more above adjacent floor or ground level will be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. The railing will be provided with a toe board wherever, beneath the open sides.
Recent events (2)
- — I (S) $3500
- — Z (S) $7000
1910.213 H01
- Issued
- Sep 27, 2012
- Abate by
- Sep 28, 2012
- Penalty
- Initial $5,000 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade was not guarded to the full diameter of the blade by a device that will automatically adjust itself to the thickness of the stock and remain in contact with stock being cut to give maximum protection possible for the operation being performed. On or about August 22, 2012, employees in the Ceiling Building department were using a Delta radial arm saw with an 8 inch saw blade, which was not provided with a guard on the lower portion of the saw blade, exposing employees to the hazard of coming in contact with the saw blade. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that the sides of the lower exposed portion of the blade will be guarded to the full diameter of the blade by a device that will automatically adjust itself to the thickness of the stock and remain in contact with stock being cut to give maximum protection possible for the operation being performed.
Recent events (2)
- — I (S) $2500
- — Z (S) $5000
1910.213 H04
- Issued
- Sep 27, 2012
- Abate by
- Sep 28, 2012
- Penalty
- Initial $4,000 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.213(h)(4): Installation shall be in such a manner that the front end of the unit will be slightly higher than the rear, so as to cause the cutting head to return gently to the starting position when released by the operator. On or about August 22, 2012, two Delta radial arm saws, one in the Saw Mill department and the other in the Exterior Bottom department, were positioned in a manner that didn't allow for the cutting head of the saw to return to the starting position, exposing employees to the hazard of coming in contact with the saw blade. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that each radial arm saw is installed in such a manner that the front end of the unit will be slightly higher than the rear, so as to cause the cutting head to return gently to the starting position when released by the operator.
Recent events (2)
- — I (S) $2000
- — Z (S) $4000
More inspections at Cavco Industries, INC.
View Cavco Industries, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321991)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335883799.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.