Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MARANATHA STUCCO Q CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MARANATHA STUCCO Q CONSTRUCTION in 15809 HOWE ST., OVERLAND PARK, KS 66224 (NAICS 238140). OSHA activity number 335890414.

Watch Maranatha Stucco Q Construction — free Get an email when a new federal OSHA severe-injury report for Maranatha Stucco Q Construction is published. One employer, no account, unsubscribe in one click.
Site address
15809 HOWE ST.
City
OVERLAND PARK
State
KS
ZIP
66224
Mailing
8821 E. WILSON RD, INDEPENDENCE, MO 64053
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.451 B01

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:    Employees engaged in applying stucco to the exterior of a house with the use of a scaffold(s) were exposed to fall hazards of approximately 6 feet from the working platform to the ground below. The employees were exposed in that the working platform was not completely planked.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.451 E01

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.    Employees engaged in applying stucco to the exterior of a house with the use of a scaffold(s) were exposed to fall hazards of approximately 6 feet from the working platform to the ground below. The employees were exposed in that an access means such as a ladder was not used to gain access onto the working platform.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.451 F03

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.451(f)(3): Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.    Employees engaged in applying stucco to the exterior of a house with the use of a scaffold(s) were exposed to fall hazards of approximately 6 feet from the working platform to the ground below. The employees were exposed in that a competent person was not available on site to inspect the structural integrity of the scaffold.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.451 C02

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.    Employees were applying stucco onto a new construction of a single family dwelling with the use of scaffolding that did not have mud sill below the base plates.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0