DOUGLASVILLE, GA —
OSHA Inspection: MZ CONSTRUCTION, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MZ CONSTRUCTION, LLC in 8732 PUETT DRIVE, DOUGLASVILLE, GA 30135 (NAICS 238130). OSHA activity number 335892006.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MZ CONSTRUCTION, LLC
- Site address
- 8732 PUETT DRIVE
- City
- DOUGLASVILLE
- State
- GA
- ZIP
- 30135
- Mailing
- 206 TAMARRON PKWY, SMYRNA, GA 30080
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.403 B02
- Issued
- Nov 20, 2012
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: Lot 179: The employer exposed employees to electrical shock hazards of 110 volts as portable tools used on the jobsite were plugged into spliced romex in lieu of an electrical outlet that was not installed as required by its listing and labeling instructions. The romex was not insulated and employees were potentially exposed to contact-with hazards based on the condition of the electrical circuit. The employer had a porter cable compressor plugged into the power supply to energize the pneumatic nail guns used on the site to install roof framing.
Recent events (1)
- — Z (S) $2000
1926.405 G02 IV
- Issued
- Nov 20, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws. Lot 179: Employees were exposed to electrical shock hazards of 110 volts as flexible cords were not supported with strain relief to prevent stress from being transmitted to joints or terminal screws. The employer had a porter cable compressor plugged into the power supply to energize the pneumatic nail guns used on the site to install roof framing.
Recent events (1)
- — Z (S) $0
1926.501 B13
- Issued
- Nov 20, 2012
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: Lot 179, residential building roof: The employer exposed employees to fall hazards of 19 feet while installing roof framing without the use of fall protection systems on a newly constructed residential home with varying roof slopes of 6 X 12 and 10 X 12.
Recent events (1)
- — Z (S) $2800
1926.503 A01
- Issued
- Nov 20, 2012
- Abate by
- Dec 10, 2012
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: Documentation and instruction: The employer exposed employees to fall hazards of 19 feet as they were not provided training regarding falls in construction prior to installing wood framing on the roof of a newly constructed home.
Recent events (1)
- — Z (S) $2000
1926.1051 A
- Issued
- Nov 20, 2012
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided: Lot 179: The employer exposed employees to fall hazards of 11 ft. while climbing the interior walls of the building to access the second level of the residential home to perform roof framing.
Recent events (1)
- — Z (S) $2000
More inspections at MZ Construction, LLC