UNADILLA, GA —
OSHA Inspection: RECYCLING REVOLUTION, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of RECYCLING REVOLUTION, LLC in 4190 COLLINS ROAD, UNADILLA, GA 31091 (NAICS 562111). OSHA activity number 335892600.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RECYCLING REVOLUTION, LLC
- Site address
- 4190 COLLINS ROAD
- City
- UNADILLA
- State
- GA
- ZIP
- 31091
- Mailing
- 4190 COLLINS ROAD, UNADILLA, GA 31091
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562111
- Employees
- 48
- Ownership type
- A
Citations
23 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 22, 2013
- Penalty
- Initial $3,500 · Current $2,000 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that the employees were exposed tro a hazard of being thrown out of the operator's seat: A) Facility, on or about August 22, 2012, a Doosan Daewoo forklift did not have a seatbelt, exposing, employees to a hazard of being thrown out of the operator's seat. One feasible and acceptable abatement method to correct this hazard is: Install a seat belt on the forklift and require employees to wear it.
Recent events (2)
- — I (S) $2000
- — Z (S) $3500
1910.110 D10
- Issued
- Jan 22, 2013
- Abate by
- Mar 8, 2013
- Penalty
- Initial $3,500 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.110(d)(10): Precautions were not taken to prevent damage to LP gas system(s) from vehicular traffic: A) Loading dock west end of building, on or about August 22, 2012, an above ground LP tank was not protected from vehicular traffic, exposing employees to a fire hazard. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $3000
- — Z (S) $3500
1910.147 C01
- Issued
- Jan 22, 2013
- Abate by
- Mar 25, 2013
- Penalty
- Initial $3,500 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: A) Facility, on or about August 22, 2012, the employer did not have a lockout/tagout program for equipment such as balers, grinders, and belt drives, exposing employees to a hazard of moving parts. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $3000
- — Z (S) $3500
1910.178 P01
- Issued
- Jan 22, 2013
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition: A) West end of building , on or abut August 2, 2012, employees operated a Caterpillar forklift that did not have an operable horn or back-up alarm, exposing employees to struck by hazards. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1910.212 A01
- Issued
- Jan 22, 2013
- Abate by
- Mar 8, 2013
- Penalty
- Initial $3,500 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. A) Missed trash conveyor, on or about September 11, 2012, the conveyor belt that serpentine over the drums was not guarded, exposing employees to an in-running nip point hazard. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $3000
- — Z (S) $3500
1910.212 A03 II
- Issued
- Jan 22, 2013
- Abate by
- Mar 8, 2013
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):(a)(LOCATION)(IDENTIFY SPECIFIC OPERATION(S) AND/OR CONDITIONS)(DESCRIBE HAZARD(S) WHERE NECESSARY) A) South west corner of building, on or about August 22, 2012, the top plate of the baler can cycle downward while the gate is in the open position, exposing employees to a crushing hazard. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $3500
1910.219 E03 I
- Issued
- Jan 22, 2013
- Abate by
- Mar 8, 2013
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): A) By sorting line, on or about September 11, 2012, the #1 and #2 grinder and the Cumberland grinder did not have the belt drive completely enclosed, exposing employees to an in-running nip point hazard. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $3500
1910.219 F03
- Issued
- Jan 22, 2013
- Abate by
- Mar 11, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: A) By pick line conveyor, on or about September 11, 2012, the chain drive to the trash conveyor was not completely enclosed, exposing employees to an in-running nip point hazard. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Jan 22, 2013
- Abate by
- Mar 11, 2013
- Penalty
- Initial $3,500 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: A) By Cumberland grinder, on or about September 11, 2012, an electrical transformer box had two unused openings near the floor, exposing employees to an electrical shock hazard. B) By computer room, on or about September 12, 2012, an electrical disconnect box had an unused opening in the side of the box, exposing employees to an electrical shock hazard. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $3000
- — Z (S) $3500
1910.305 D02
- Issued
- Jan 22, 2013
- Abate by
- Mar 8, 2013
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(d)(2): Panelboard enclosures. Panelboards mounted in cabinets, cutout boxes, or enclosures designed for the purpose were not dead front. A) By computer room, on or about September 11,2012, the surface mounted breaker panel had opening in the face plate, exposing employees to an electrical shock hazard. B) On the south wall, on or about December 20, 2012, the surface mounted breaker panel did not have a dead front, exposing employees to an electrical shock hazard. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $3500
1910.335 B01
- Issued
- Jan 22, 2013
- Abate by
- Mar 8, 2013
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.335(b)(1): Safety signs, safety symbols, or accident prevention tags were not used where necessary to warn employees about electrical hazards which may endanger them, as required by 1910.145. A) By the computer room, on or about December 20, 2012, the employer did not post signs or accident prevention tags around the area where energized parts in a breaker panel were accessible, exposing employees to an electrical shock hazard. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $3500
1910.335 B02
- Issued
- Jan 22, 2013
- Abate by
- Mar 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(b)(2): Barricades were not used in conjunction with safety signs where it was necessary to prevent or limit employee access to work areas in which employees were exposed to uninsulated energized conductors or circuit parts: A) By the computer room, on or about December 20, 2012, the employer did not barricade the area where energized parts in a breaker panel were accessible to employees, exposing employees to an electrical shock hazard. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.110 E04 III
- Issued
- Jan 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.110(e)(4)(iii): Permanent and removable fuel containers were not securely mounted to prevent jarring loose, slipping, or rotating: A) By loading dock, on or about August 22, 2012, the propane gas cylinder mounted on the back of a Caterpillar forklift was not properly secured. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.110 H06 I B
- Issued
- Jan 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.110(h)(6)(i)(b): Readily ignitable material including weeds and long dry grass, were not removed within 10 feet of containers. A) Loading dock area west end of building, on or about September 11, 2012, cardboard and other debris was allowed to accumulate around an above ground LP gas tank. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 E03
- Issued
- Jan 22, 2013
- Abate by
- Mar 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: A) Throughout facility, on or about August 22, 2012, portable fire extinguishers had not had an annual inspection since calendar year 2010, exposing employees to a fire hazard. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B02
- Issued
- Jan 22, 2013
- Abate by
- Mar 11, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: A) By the number 2 grinder, on or about August 22, 2012, the junction box on the out feed conveyor motor to the number 2 grinder did not have a cover plate. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Jan 22, 2013
- Abate by
- Mar 11, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: A) By computer room, on or about September 11, 2012, electrical wires leaving the top of a breaker panel to provide power to equipment was not installed in conduit. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G02 II
- Issued
- Jan 22, 2013
- Abate by
- Mar 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: A) Pick line, on or about August 22, 2012, a multiple plug Pig Tail was spliced to a extension cord, exposing employees to an electrical shock hazard. B) Behind pick line, on or about August 22, 2012, the electrical power cord to the motor of the conveyor to the #2 grinder was spliced, exposing employees to an electrical shock hazard. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G02 III
- Issued
- Jan 22, 2013
- Abate by
- Mar 11, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: A) Behind the #2 grinder, on or about August 22, 2012, an electrical cord entering a junction box to a motor on the out feed conveyor was not provided with strain relief. B) Marathon Baler, on or about September 11, 2012, the strain relief device was pulled out of the control box allowing strain to be placed on the electrical wires. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 I02 I
- Issued
- Jan 22, 2013
- Abate by
- Mar 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(i)(2)(i): Fixture wires used for installation in lighting fixtures and in similar equipment were not enclosed or protected and were subject to bending or twisting in use: A) Tumbler platform, on or about September 12, 2012, the wires for a fluorescent light fixture were not enclosed or protected, exposing employees to an electrical shock hazard. B) Walking area in plant by main office, on or about August 22, 2012, the wires for a fluorescent light fixture were not enclosed or protected, exposing employees to an electrical shock hazard. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.37 A03
- Issued
- Jan 22, 2013
- Penalty
- Initial $2,800 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: A) West end of building, on or about August 22, 2012, exit doors on the south end of the building were blocked, exposing employees to a hazard of not being able to quickly exit the building incase of an emergency. B) North east side of building, on or about August 22, 2012, an exit door on the west side of The building was blocked, exposing employees to a hazard of not being able to quickly exit the building incase of an emergency.
Recent events (2)
- — I (O) $1000
- — Z (S) $2800
1910.110 F02 II
- Issued
- Jan 22, 2013
- Abate by
- Mar 8, 2013
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.110(f)(2)(ii): Containers when stored inside were located near exits, stairways, or in areas normally used or intended for the safe exit of people. A) West end of building, on or about August 22, 2012, portable liquefied propane bottles were stored by the exit door, exposing employee to a fire hazard and or not being able to exit the building. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (O) $0
- — Z (S) $3500
1910.144 A03
- Issued
- Jan 22, 2013
- Abate by
- Mar 8, 2013
- Penalty
- Initial $2,100 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.144(a)(3): Yellow was not the basic color for designating caution and for marking physical hazards such as: Striking against, stumbling, falling, tripping, and caught in between: A) Behind pick line, on or about September 11, 2012, the sides of the grinder conveyors were not color coded in yellow to alert the employees of the incline conveyors. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (O) $1000
- — Z (S) $2100
More inspections at Recycling Revolution, LLC
View Recycling Revolution, LLC's full OSHA safety record →
More inspections in this industry (NAICS 562111)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335892600.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.