BAYSIDE, NY —
OSHA Inspection: AIR SERVICE PRO INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AIR SERVICE PRO INC. in 242-02 61 ST AVENUE, BAYSIDE, NY 11361 (NAICS 333415). OSHA activity number 335916003.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AIR SERVICE PRO INC.
- Site address
- 242-02 61 ST AVENUE
- City
- BAYSIDE
- State
- NY
- ZIP
- 11361
- Mailing
- 325 PENINSULA BLVD, CEDARHURST, NY 11516
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333415
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.23 C01
- Issued
- Feb 11, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard: a) On or about August 15, 2012-Job Site at 242-02 61 St Avenue Bayside, NY 11361 Employee on the roof pulling HVAC wire exposed to falls of 12-feet. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.333 B02
- Issued
- Feb 11, 2013
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.333(b)(2): While an employee was exposed to contact with parts of fixed electric equipment or circuits which were deenergized, the circuits energizing the parts were not locked out or tagged or both in accordance with the requirements of this paragraph (b) of 29 CFR 1910.333(b)(2): On or about August 15, 2012-Job Site at 242-02 61 St Avenue Bayside, NY 11361 a) Employee pulling HVAC control wire through an open 220 volt panel did not lock out both power switches. WRITTEN ABATEMENT DOCUMENTATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $2000
More inspections in this industry (NAICS 333415)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335916003.