Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KOMATSU AMERICA CORP.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of KOMATSU AMERICA CORP. in 2300 N.E. ADAMS ST., PEORIA, IL 61639 (NAICS 333131). OSHA activity number 335920583.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Komatsu America Corp. — free Get an email when a new federal OSHA severe-injury report for Komatsu America Corp. is published. One employer, no account, unsubscribe in one click.
Site address
2300 N.E. ADAMS ST.
City
PEORIA
State
IL
ZIP
61639
Mailing
2300 N.E. ADAMS ST., PEORIA, IL 61639
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333131
Employees
926
Ownership type
A

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 40 exposed
Issued
Feb 21, 2013
Abate by
Apr 9, 2013
Penalty
Initial $7,000 · Current $7,000
OSH ACT of 1970 Section (5)(a)(1):     The employer did not furnish a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to severe struck by hazards when testing new hydraulic cylinders for leakage:    The employer failed to ensure all components installed and operated on the old hoist test stand were properly designed, specified and rated for the intended operating parameters when testing new hydraulic cylinders in building AA.  On or about August 22, 2012, the hydraulic coupler on the return line catastrophically failed, fatally injuring the employee.  The hydraulic coupler on this machine also catastrophically failed in 2008 and 2010.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $7000

1910.147 C06 I A

Serious Gravity 5 1 instance 35 exposed
Issued
Feb 21, 2013
Abate by
Oct 15, 2013
Penalty
Initial $5,000 · Current $5,000
29 CFR 1910.147(c)(6)(i)(A):     The periodic inspection of the energy control procedure was not performed by an authorized employee other than the one utilizing the energy control procedure being inspected:    In Building AA, the periodic inspection was conducted by the same employee that performed the servicing and/or maintenance.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $5000

1910.147 C06 I C

Serious Gravity 5 1 instance 35 exposed
Issued
Feb 21, 2013
Abate by
Oct 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i)(C):     Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected:    Employees were exposed to hazardous energy when performing servicing and maintenance activities in building AA because energy control procedure inspections for equipment such as, but not limited to, the Rear Brake Test Stand and Spindle/Hub Test Stand were not conducted by the inspector and each authorized employee.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 II

Deleted Serious Gravity 5 1 instance 35 exposed
Issued
Feb 21, 2013
Abate by
Apr 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii):     The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection:    Employees were exposed to hazardous energy when performing servicing and maintenance activities in building AA because there were no certifications indicating periodic inspections had taken place.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 II

Repeat Gravity 10 1 instance 35 exposed
Issued
Feb 21, 2013
Abate by
Oct 15, 2013
Penalty
Initial $35,000 · Current $35,000
29 CFR 1910.147(c)(4)(ii):     The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section:    Employees were exposed to hazardous energy when performing servicing and maintenance tasks on the Rear Brake Test Stand and Spindle/Hub Test Stand in building AA because specific energy control procedures did not identified the equipment to be used, areas to attach the lockout devices, source(s) and type(s) of hazardous energy, nor identify authorized user responsibilities.    THE KOMATSU AMERICA CORP. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1910.147(c)(4)(ii) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 314848045, CITATION NUMBER 1, ITEM NUMBER 1, AND WAS AFFIRMED AS A FINAL ORDER ON JANUARY 24, 2011, WITH RESPECT TO A WORKPLACE LOCATED AT 2300 N. E. ADAMS STREET, PEORIA, IL 61639.
Recent events (2)
  • — I (R) $35000
  • — Z (R) $35000

1910.147 C07 III A

Serious Gravity 10 1 instance 35 exposed
Issued
Feb 21, 2013
Abate by
Oct 15, 2013
Penalty
Initial $35,000 · Current $7,000 Reduced
29 CFR 1910.147(c)(7)(iii)(A):     The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices:    Employees performing servicing and maintenance tasks on the machines in building AA were exposed to hazardous energy because they had not received training that described the equipment to be used in specific applications, areas to attach the lockout devices, source(s) and type(s) of hazardous energy specific to different machines, nor identify authorized user responsibilities.    THE KOMATSU AMERICA CORP. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1910.147(c)(7)(i) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 314848045, CITATION NUMBER 1, ITEM NUMBER 2, AND WAS AFFIRMED AS A FINAL ORDER ON JANUARY 24, 2011, WITH RESPECT TO A WORKPLACE LOCATED AT 2300 N. E. ADAMS STREET, PEORIA, IL 61639.
Recent events (2)
  • — I (S) $7000
  • — Z (R) $35000

View Komatsu America Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335920583.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.