Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BONDED ROOFING SERVICES INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BONDED ROOFING SERVICES INC. in 4635 N. UNIVERSITY DRIVE, CORAL SPRINGS, FL 33067 (NAICS 238160). OSHA activity number 335924346.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bonded Roofing Services INC. — free Get an email when a new federal OSHA severe-injury report for Bonded Roofing Services INC. is published. One employer, no account, unsubscribe in one click.
Site address
4635 N. UNIVERSITY DRIVE
City
CORAL SPRINGS
State
FL
ZIP
33067
Mailing
2303 WEST MCNAB ROAD STE #4, POMPANO BEACH, FL 33069
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.501 B10

Serious Gravity 5 2 instances 3 exposed
Issued
Aug 30, 2012
Abate by
Sep 7, 2012
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.      On or about 08-23-12, employees doing roofing work were not protected from falls by any type of fall protection.  On or about 08-24-12, the superintendent, while doing roofing activity was not protected by any type of fall protection.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.502 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 30, 2012
Abate by
Sep 7, 2012
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.502(d)(1): Personal fall arrest system connectors were not drop forged, pressed or formed steel, or made of equivalent materials:    On or about 08-24-12, an employee was attached to an aerial lift and to his harness by means of knots.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

View Bonded Roofing Services INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335924346.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.