BLACKWOOD, NJ ·
OSHA Inspection: EAGLE RECONDITIONING SERVICE INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of EAGLE RECONDITIONING SERVICE INC. in 500 UNIVERSITY COURT, BLACKWOOD, NJ 08012 (NAICS 423840). OSHA activity number 335958781.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EAGLE RECONDITIONING SERVICE INC.
- Site address
- 500 UNIVERSITY COURT
- City
- BLACKWOOD
- State
- NJ
- ZIP
- 08012
- Mailing
- 500 UNIVERSITY COURT, BLACKWOOD, NJ 08012
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423840
- Employees
- 20
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
1910.24 B
- Issued
- Oct 16, 2012
- Abate by
- Dec 6, 2012
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.24(b): Fixed stairs were not provided for access from one structure level to another where operations necessitated regular travel between levels, and for access to operating platforms at any equipment which requires attention routinely during operations: a) Eagles Reconditioning Service Inc. 500 University Court, Blackwood, NJ 08012: Fixed ladders were not provided by the employer to facilitate access of employees to different work level platforms located next to the conveyor system, observed on or about 8/14/2012.
Recent events (2)
- · I (S) $600
- · Z (S) $1200
1910.132 D01
- Issued
- Oct 16, 2012
- Abate by
- Dec 6, 2012
- Penalty
- Initial $2,000 · Current $600 Reduced
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): a) Eagles Reconditioning Service Inc. 500 University Court, Blackwood, NJ 08012: The employer did not conduct a hazard assessment analysis to determine the need for appropriate personal protective equipment (PPE), such as cut and puncture resistant gloves for the employees cleaning and handling broken glassware, occurred on or about 8/14/2012.
Recent events (2)
- · I (S) $600
- · Z (S) $2000
1910.138 A
- Issued
- Oct 16, 2012
- Abate by
- Dec 6, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes. a) Eagles Reconditioning Service Inc. 500 University Court, Blackwood, NJ 08012: The employer did not select and required employees to use puncture and/or cut resistant gloves when handling broken glassware, observed on or about 08/14/2012.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.157 G02
- Issued
- Oct 16, 2012
- Abate by
- Dec 6, 2012
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: a) Eagles Reconditioning Service Inc. 500 University Court, Blackwood, NJ 08012. The employer did not provide training to employees to familiarize them with the general principals of fire extinguisher use and the hazards involved with incipient stage fire fighting, occurred on or about 8/14/2012. BY THIS DATE THE EMPLOYER MUST EITHER CORRECT THE ALLEGED VIOLATION(S) OR IMPLEMENT A FIRE SAFETY POLICY, AS OUTLINED IN 29 CFR 1910.38 WHICH INCLUDES THE EVACUATION REQUIRMENTS OF 29 CFR 1910.157(b).
Recent events (2)
- · I (S) $600
- · Z (S) $1200
1910.305 B01 II
- Issued
- Oct 16, 2012
- Abate by
- Dec 6, 2012
- Penalty
- Initial $2,000 · Current $600 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) Eagles Reconditioning Service Inc. 500 University Court, Blackwood, NJ 08012: Two circuit breakers were missing in the electrical panel located next to the emergency exit, on or about 8/14/2012.
Recent events (2)
- · I (S) $600
- · Z (S) $2000
1910.305 G01 IV A
- Issued
- Oct 16, 2012
- Abate by
- Dec 6, 2012
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for the fixed wiring of a structure; a) Eagles Reconditioning Service Inc. 500 University Court, Blackwood, NJ 08012: Extensions cords were used near the electrical box to power an fan, power strip, and radio, observed on and about 8/14/2012. b) Eagles Reconditioning Service Inc. 500 University Court, Blackwood, NJ 08012: Extensions cords were used near a work station to power lamp, power strip, and hand tool, observed on and about 8/14/2012.
Recent events (2)
- · I (S) $600
- · Z (S) $1200
1910.303 B02
- Issued
- Oct 16, 2012
- Abate by
- Dec 6, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: The employer used power strips to supply electric power to multiple devices and as a substitute of fixed outlets; a) Eagles Reconditioning Service Inc. 500 University Court, Blackwood, NJ 08012: Power strips were used at the work station near the electrical box to power devices such as a fan and a radio, observed on and about 8/14/2012. b) Eagles Reconditioning Service Inc. 500 University Court, Blackwood, NJ 08012: Power strips were used at the work station located at the end of the conveyor to power devices such as a lamp and hand tools, observed on and about 8/14/2012.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 423840)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 335958781.