JACKSONVILLE, FL —
OSHA Inspection: U.S. METAL TRADING, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of U.S. METAL TRADING, INC. in 614 MCDUFF AVE N., JACKSONVILLE, FL 32254 (NAICS 423930). OSHA activity number 335959193.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. METAL TRADING, INC.
- Site address
- 614 MCDUFF AVE N.
- City
- JACKSONVILLE
- State
- FL
- ZIP
- 32254
- Mailing
- 614 MCDUFF AVE N., JACKSONVILLE, FL 32254
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.253 B05 III I
- Issued
- Sep 26, 2012
- Abate by
- Oct 18, 2012
- Penalty
- Initial $1,760 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.253(b)(5)(iii)(I): Suitable regulators for reducing the pressure were not attached to the cylinders' valves when fuel-gas was used through torches: a. On or about August 28, 2012, the oxygen tank regulator had a defective pressure gage. b. On or about August 28, 2012, the oxygen and propane regulators did not have reverse-flow check valves.
Recent events (2)
- — I (S) $1200
- — Z (S) $1760
1910.253 E05 III
- Issued
- Sep 26, 2012
- Abate by
- Oct 18, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(e)(5)(iii): Hose connections for oxy-fuel gas service did not comply with the Standard Hose Connection Specifications, 1957, Compressed Gas Association: a. On or about August 28, 2012, the oxygen and propane torch hoses were connected to the regulators with worm drive clamps.