Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ACTION ROOFING & SIDING LLC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ACTION ROOFING & SIDING LLC. in 25 OAKWOOD AVE, RYE, NY 10580 (NAICS 238160). OSHA activity number 335974200.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Action Roofing & Siding LLC. — free Get an email when a new federal OSHA severe-injury report for Action Roofing & Siding LLC. is published. One employer, no account, unsubscribe in one click.
Site address
25 OAKWOOD AVE
City
RYE
State
NY
ZIP
10580
Mailing
707 E. 189TH STREET, BRONX, NY 10458
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 11, 2013
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.    Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection system. Accordingly the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926. 502(k) for a particular workplace situation, in lieu of implementing any of those systems.     a) Job Site, 25 Oakwood Ave, Rye, NY,:  Three (3) employees working on the roof removing old shingles and installing new ones were not protected from falling approximately 20' feet below; on or about 8/23/12.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1926.503 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 11, 2013
Abate by
Mar 8, 2013
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.503(a)(1): The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards.    a) Job Site, 25 Oakwood Ave, Rye, NY:  Employees performing roofing work were not trained in fall hazard recognition or procedures to minimize hazards assiciated with the falls; on or about 8/23/12.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.1053 B16

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 11, 2013
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with "Do Not Use" or similar language, and shall be withdrawn from service until repaired:    a) Job Site, 25 Oakwood Ave, Rye, NY, Driveway of the Garage Side:  A damaged Werner 32' aluminum extension ladder used by employees to gain access/egress to the roof was not identified as defective, tagged with "Do not use", or withdrawn from service, 8/23/2012.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

View Action Roofing & Siding LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335974200.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.