WASHINGTON, PA —
OSHA Inspection: MASTER WOODCRAFT CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MASTER WOODCRAFT CORPORATION in 100 STATIONVUE STREET, WASHINGTON, PA 15301 (NAICS 337110). OSHA activity number 335986782.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MASTER WOODCRAFT CORPORATION
- Site address
- 100 STATIONVUE STREET
- City
- WASHINGTON
- State
- PA
- ZIP
- 15301
- Mailing
- 100 STATIONVUE STREET, WASHINGTON, PA 15301
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 19
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.134 E01
- Issued
- Sep 27, 2012
- Abate by
- Oct 19, 2012
- Penalty
- Initial $1,200 · Current $800 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator before the employee was fit tested or required to use the respirator in the workplace: Facility- 100 Stationvue, Washington, PA: On or about August 28, 2012, employees required to wear a half-face cartridge respirator while working in spray booths were not provided with an initial medical evaluation.
Recent events (2)
- — I (S) $800
- — Z (S) $1200
1910.134 F
- Issued
- Sep 27, 2012
- Abate by
- Nov 19, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f): The employee was required to use a respirator without being fit tested with the same make, model, style and size of respirator that was to be used: (a) Facility- 100 Stationvue, Washington, PA: On or about August 28, 2012, employees required to wear a half-face cartridge respirator while working in spray booths were not annually fit tested.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Sep 27, 2012
- Abate by
- Oct 19, 2012
- Penalty
- Initial $1,440 · Current $900 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices: (a) Facility- 100 Stationvue, Washington, PA: On or about August 28, 2012, employees such as but not limited to affected, authorized, and other employees were provided with lock out/tag out training.
Recent events (2)
- — I (S) $900
- — Z (S) $1440
1910.213 D01
- Issued
- Sep 27, 2012
- Abate by
- Oct 4, 2012
- Penalty
- Initial $1,600 · Current $1,100 Reduced
General-duty citation text
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: Facility- 100 Stationvue, Washington, PA: On or about August 28, 2012, an employee was observed bypassing the guard on the Powermatic table saw while cutting a notch in a piece of wood for a wall cabinet.
Recent events (2)
- — I (S) $1100
- — Z (S) $1600
1910.1200 H01
- Issued
- Sep 27, 2012
- Abate by
- Oct 19, 2012
- Penalty
- Initial $1,080 · Current $0 Reduced
General-duty citation text
29 CFR 1910.1200(h)(1): The employer did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees had not previously been trained about was introduced into their work area. (a) Facility- 100 Stationvue, Washington, PA: On or about August 28, 2012, employees working with hazardous chemicals such as but not limited to MagnaKlear, Melamine Adhesive, and Permagrip have not received hazard communication training.
Recent events (2)
- — I (O) $0
- — Z (S) $1080
1910.178 L04 III
- Issued
- Sep 27, 2012
- Abate by
- Oct 19, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operators performance was not conducted at least once every 3 years: (a) Facility- 100 Stationvue, Washington, PA: On or about August 28, 2012, the employer did not provide refresher training for all employees that operate the Hyster Forklift.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Sep 27, 2012
- Abate by
- Oct 12, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) Facility- 100 Stationvue, Washington, PA: On or about August 28, 2012, an extension cord was supplying power to a DeWalt Aluminum Cut-off saw. The saw has been plugged into this extension cord for approximately one year.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Master Woodcraft Corporation
View Master Woodcraft Corporation's full OSHA safety record →
More inspections in this industry (NAICS 337110)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335986782.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.