Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: G.S. KUSICH CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of G.S. KUSICH CONSTRUCTION, INC. in 1760 BROADWAY AVENUE, HERMITAGE, PA 16148 (NAICS 238160). OSHA activity number 335996989.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch G.S. Kusich Construction, INC. — free Get an email when a new federal OSHA severe-injury report for G.S. Kusich Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1760 BROADWAY AVENUE
City
HERMITAGE
State
PA
ZIP
16148
Mailing
380 FREDONIA ROAD, GREENVILLE, PA 16125
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.501 B10

Serious Gravity 10 1 instance 5 exposed
Issued
Jan 4, 2013
Abate by
Jan 31, 2013
Penalty
Initial $2,800 · Current $1,700 Reduced
29 CFR 1926.501(b)(10):     Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and fuardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system.    A.)  G.S. Kusich Construction, Inc., 1760 Broadway Avenue, Hermitage, PA  16148, east roof, on or about 08/21/2012 and times prior thereto:  Employees performing roofing work at the peak of a 4:12 pitch roof, were working at edge on the north side of the roof 47 feet above ground level without a means or method of fall protection.
Recent events (2)
  • — I (S) $1700
  • — Z (S) $2800

1926.502 F01 I

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 4, 2013
Abate by
Jan 31, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.502(f)(1)(i):     When no mechanical equipment was being used the warning line was not erected at least 6 feet (1.8m) from the roof edge:    A.)  G.S. Kusich Construction, Inc., 1760 Broadway Avenue, Hermitage, PA  16148, west roof, on or about 08/21/2012 and times prior thereto:  A warning line system was utilized for personnel walking/working on a flat roof located 27 feet above ground level.  The warning line system on the west side of the structure was 2.7 feet from the edge of the roof line.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.502 F01

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 4, 2013
Abate by
Jan 31, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.502(f)(1):     Warning lines were not erected around all sides of the roof work area:    A.)  G.S. Kusich Construction, Inc., 1760 Broadway Avenue, Hermitage, PA  16148, west roof, on or about 08/21/2012 and times prior thereto:  A warning line system was utilized for personnel walking/working on a flat roof located 27 feet above ground level.  The warning line was not erected on the southwest side of the roof to complete a full perimeter around the flat roof area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 F01 III

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 4, 2013
Abate by
Jan 31, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.502(f)(1)(iii):     Points of access, material handling areas, storage areas, and/or hoisting areas were not connected to the work area by an access path formed by two warning lines:    A.)  G.S. Kusich Construction, Inc., 1760 Broadway Avenue, Hermitage, PA  16148, west roof, on or about 08/21/2012 and times prior thereto:  A warning line system was utilized for personnel walking/working on a flat roof located 27 feet above ground level.  The warning line system was not erected as to form a path to the ladder access.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 F02 II

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 4, 2013
Abate by
Jan 31, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.502(f)(2)(ii):     The rope, wire, or chain was not rigged or supported in such a way that its lowest point (including sag) was not less than 34 inches (0.9 m) from the walking/working surface and its highest point no more than 39 inches (1.0 m) from the walking/working surface.    A.)  G.S. Kusich Construction, Inc., 1760 Broadway Avenue, Hermitage, PA  16148, west roof, on or about 08/21/2012 and times prior thereto:  A warning line system was utilized for personnel walking/working on a flat roof located 27 feet above ground level.  The warning line height was 12-18 inches from the roof surface.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View G.S. Kusich Construction, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335996989.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.