Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CLIQUE HERE, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CLIQUE HERE, INC. in 2500 PARK CENTRAL BLVD. STE. A-6, DECATUR, GA 30035 (NAICS 452910). OSHA activity number 336006184.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Clique Here, INC. — free Get an email when a new federal OSHA severe-injury report for Clique Here, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
CLIQUE HERE, INC.
Site address
2500 PARK CENTRAL BLVD. STE. A-6
City
DECATUR
State
GA
ZIP
30035
Mailing
2500 PARK CENTRAL BLVD. STE. A-6, DECATUR, GA 30035
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
452910
Employees
7
Ownership type
A

7 citations on file for this inspection.

1910.37 B02

Serious Gravity 1 1 instance 7 exposed
Issued
Sep 13, 2012
Abate by
Sep 14, 2012
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":    On or about 8/29/12 at 2500 Park Central Blvd. Ste. A-6 Decatur, GA; employees were exposed to potential smoke inhalation and burn hazards where the emergency exit light was inoperative. There were no bulbs nor "EXIT" sign in the designed EXIT frame.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1910.157 E02

Serious Gravity 1 1 instance 7 exposed
Issued
Sep 13, 2012
Abate by
Sep 14, 2012
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1910.157(e)(2):  Portable fire extinguishers were not visually inspected at least monthly:    On or about 8/29/12 at 2500 Park Central Blvd. Ste. A-6 Decatur, GA; employees were exposed to potential smoke inhalation and burn hazards where the portable fire extinguishers were not inspected on a monthly basis.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1910.157 E03

Serious Gravity 1 1 instance 7 exposed
Issued
Sep 13, 2012
Abate by
Sep 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:    On or about 8/29/12 at 2500 Pake Central Blvd. Ste. A-6 Decatur, GA; employees  working in the warehouse were exposed to potential smoke inhalation and burn hazards where the portable fire extinguishers were not inspected annually.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 13, 2012
Abate by
Sep 20, 2012
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    On or about 8/29/12 at 2500 Park Central Blvd. Ste. A-6 Decatur, GA; employees working in the warehouse were exposed to electrical hazards where the 110 V, metallic, duplex pendant did not meet the listing and labeling requirements. The pendant was designed for wall mounted use.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.303 B07 I

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 13, 2012
Abate by
Sep 20, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment.    On or about 8/29/12 at 2500 Park Central Blvd. Ste. A-6 Decatur, GA; an employee working in the warehouse was exposed to electrical hazards where the 110 V., metallic, duplex pendant had an unused opening exposing the employee to the internal energized parts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 13, 2012
Abate by
Sep 20, 2012
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    On or about 8/29/12 at 2500 Park Central Blvd. Ste. A-6 Decatur, GA; employees were exposed to potential electrical burns where a 110 V electrical box mounted to the wall in the Pick n pack cardboard storage area at a height of 68" (5'8") had exposed live wires and was not covered.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.178 L

Other-than-serious 1 instance 1 exposed
Issued
Sep 13, 2012
Abate by
Sep 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l): Operators were not trained in the safe operation of powered industrial trucks:    On or about 8/29/12 at 2500 Park Central Blvd. Ste. A-6 Decatur, GA; employees working in the warehouse were exposed to struck-by hazards where the employer failed to ensure that employees were formally trained, by the standard, to operate the powered industrial truck. (Written examination, formal instruction, video, etc.)
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336006184.