OSHA Inspection: LIDYO MOLINA

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of LIDYO MOLINA in 5001 MONTCLAIR DRIVE, COLLEYVILLE, TX 76034 (NAICS 238160). OSHA activity number 336010780.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lidyo Molina — free Get an email when a new federal OSHA severe-injury report for Lidyo Molina is published. One employer, no account, unsubscribe in one click.
Establishment
LIDYO MOLINA
Site address
5001 MONTCLAIR DRIVE
City
COLLEYVILLE
State
TX
ZIP
76034
Mailing
961 E. TERRELL AVE, FORT WORTH, TX 76104
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.416 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 18, 2012
Abate by
Oct 23, 2012
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:    On or about August 29, 2012, employees performing roofing activities used portable hand tools powered by flexible extension cords that were worn, cut, and had pulled wires with exposed conductors.  Employees were exposed to electrical shock hazards.
Recent events (1)
  • — Z (S) $2000

1926.501 B13

Serious Gravity 10 3 instances 3 exposed
Issued
Oct 18, 2012
Abate by
Oct 23, 2012
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502.      On or about August 29, 2012, employees working on a residential roof installing roofing tiles were not wearing personal fall protection nor protected from falling by other means of fall protective systems.  Employees were exposed to the hazard of falling.    a) On the top edge of the garage roof, an employee was exposed to the hazard of falling approximately 16 feet to the ground below.      b) On the top chimney roof, an employee was exposed to the hazard of falling approximately 28 feet to the ground below.    c) On the residential roof next to the chimney, an employee was assisting with tools and material and exposed to the hazard of falling approximately 12 feet to the ground below.
Recent events (1)
  • — Z (S) $2800

View Lidyo Molina's full OSHA safety record →