MARSHALL, TX —
OSHA Inspection: FASON TREE SERVICE
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of FASON TREE SERVICE in ONE TIGER DRIVE, MARSHALL, TX 75670 (NAICS 561730). OSHA activity number 336011390.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FASON TREE SERVICE
- Site address
- ONE TIGER DRIVE
- City
- MARSHALL
- State
- TX
- ZIP
- 75670
- Mailing
- 209 FAIRVIEW STREET, MARSHALL, TX 75672
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561730
- Employees
- 2
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.332 B01
- Issued
- Jan 31, 2013
- Abate by
- Feb 5, 2013
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments: The employer does not ensure that employees are trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertain to their respective job assignments. This violation occurred on August 1, 2012; when the employer did not train and ensure that at least one (1) employee was familiar with safety-related work practices pertaining to cutting tree limbs while working from an aerial lift near energized overhead power lines.
Recent events (3)
- — F (S) $0
- — C (S) $2800
- — Z (S) $2800
1910.332 B02
- Issued
- Jan 31, 2013
- Abate by
- Feb 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.332(b)(2): Employees who were covered by 29 CFR 1910.332(a) but who were not qualified persons were not trained in and familiar with any electrically-related safety practices not specifically addressed by 1910.331 through 1910.335 but which were necessary for their safety: The employer does not ensure that unqualified employees, who perform tree cutting work from aerial lifts near energized overhead powerlines are trained in and familar electrically-related safety practices necessary for their safety. This violation occurred on August 1, 2012, when an unqualified employee performed tree cutting work from an aerial lift near energized overhead power lines and was not trained in and familiar with electrically-related safety practices which were necessary for his safety. Electrically-related safety practices include, but are not limited to: Determining nominal voltatge of the power lines near which employees will be working; Need for second employee to communicate line clearance; and Minimum approach distances when tree limbs are contacting energized overhead power lines.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.333 C03 I A 1
- Issued
- Jan 31, 2013
- Abate by
- Feb 5, 2013
- Penalty
- Initial $2,800 · Current $2,100 Reduced
General-duty citation text
1910.333(c)(3)(i)(A)(1): When an unqualified person was working in an elevated position near overhead lines with voltages to ground 50kV or below, the location was not such that the person and the longest conductive object he or she could contact could not come closer to any unguarded, energized overhead line than 10 feet (305 cm): The employer does not ensure that when an unqualified employee is working in an elevated position near overhead lines with voltages to ground 50 kV or below, the location is such that the employee and the longest conductive object the employee could contact cannot come closer to energized overhead line than 10 feet. This violation occurred on August 1, 2012; when an unqualified employee worked from a non-insulated aerial lift basket lat a distance closer than 10 feet of energized overhead lines while was using a non-insulated telescoping pole pruner to cut tree limbs.
Recent events (3)
- — F (S) $2100
- — C (S) $2800
- — Z (S) $2800
1910.333 C03 III A
- Issued
- Jan 31, 2013
- Abate by
- Feb 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(c)(3)(iii)(A): Any vehicle or mechanical equipment which was capable of having parts of its structure elevated near energized overhead lines was not operated so that a clearance of 10 ft. (305 cm) was maintained: The employer does not enusre that aerial lifts maintain a 10-foot clearance from energized overhead lines. This violation occurred on August 1, 2012; when employee, who was working from when cutting tree limbs from an aerial lift, approached energized overhead power lines closure than 10 feet.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.335 A01 I
- Issued
- Jan 31, 2013
- Abate by
- Feb 5, 2013
- Penalty
- Initial $2,800 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with, and did not use, electrical protective equipment that was appropriate for the specific parts of the body to be protected and for the work that was performed: The employer does not provide and ensure that employees use electrical protective equipment that insulate their arms and hands from electrical hazards. This violation occurred on August 1, 2012; when an employee, who was cutting tree limbs near energized overhead power lines, was not provided with nor using electrical protective gloves.
Recent events (3)
- — F (S) $2100
- — C (S) $2800
- — Z (S) $2800
1910.335 A02 I
- Issued
- Jan 31, 2013
- Abate by
- Feb 7, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(2)(i): When working near exposed energized conductors or circuit parts, each employee did not use insulated tools or handling equipment when the tools or handling equipment might have made contact with such conductors or parts: When working near exposed energized conductors or circuit parts, the employer does not ensure that each employee uses insulated tools or handling equipment when the tools or handling equipment can make contact with such conductors or parts. The violation occurred on August 1, 2012; when an employee used a non-insulated telescoping pole pruner saw near energized overhead power lines.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1904.39 A
- Issued
- Jan 31, 2013
- Abate by
- Feb 5, 2013
- Penalty
- Initial $1,000 · Current $750 Reduced
General-duty citation text
29 CFR 1904.39(a): Within eight (8) hours after the death of any employee from a work-related incident, the employer did not orally report the fatality to the Area Office of the Occupational Safety and Health Administration (OSHA) that is nearest to the site of the incident or use the OSHA toll-free central telephone number, 1-800-321-OSHA (1-800-321-6742): On August 1, 2012, within eight (8) hours after the death of an employee, the employer did not orally report the incident to OSHA.
Recent events (3)
- — F (O) $750
- — C (O) $1000
- — Z (O) $1000
More inspections in this industry (NAICS 561730)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336011390.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.