Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RVM CONSTRUCTION CORP.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of RVM CONSTRUCTION CORP. in 455 MISTLETOE WAY, LAWRENCE, NY 11559 (NAICS 238130). OSHA activity number 336017801.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch RVM Construction Corp. — free Get an email when a new federal OSHA severe-injury report for RVM Construction Corp. is published. One employer, no account, unsubscribe in one click.
Site address
455 MISTLETOE WAY
City
LAWRENCE
State
NY
ZIP
11559
Mailing
622 HENDERSON AVE., STATEN ISLAND, NY 10310
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
7
Ownership type
A

5 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 7 exposed
Issued
Sep 7, 2012
Abate by
Sep 10, 2012
Penalty
Initial $2,000 · Current $750 Reduced
29 CFR 1926.100(a):  Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns:      a)  Worksite, Exterior - Employees framing a two story residential home were not wearing protective helmets while working below overhead materials and tools; on or about 8/28/12.      Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $750
  • — Z (S) $2000

1926.252 A

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 7, 2012
Abate by
Sep 10, 2012
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.252(a):   An enclosed chute of wood, or equivalent material, was not used where materials were dropped more than 20 feet to points lying outside the exterior walls of the building(s):    a)  Worksite, Exterior - Employees were throwing cut pieces of plywood off a roof approximately 35ft to the ground below; on or about 8/28/12.      Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.304 D

Serious Gravity 10 2 instances 5 exposed
Issued
Sep 7, 2012
Penalty
Initial $2,800 · Current $1,000 Reduced
29 CFR 1926.304(d):  Portable, power-driven circular saw(s) were not equipped with a guard above and below the base plate or shoe:      a)  Worksite, Interior, first floor - An employee was using a Makita Circular Saw, #5007MG, to cut lumber with the guard wedged in the open position; on or about 8/28/12.    b)  Worksite, Interior, second floor - Employees were using a Makita Circular Saw, #5007MG, to cut plywood with the guard wedged in the open position: on or about 8/28/12.        Note:   Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2800

1926.501 B13

Serious Gravity 10 3 instances 7 exposed
Issued
Sep 7, 2012
Abate by
Sep 10, 2012
Penalty
Initial $2,800 · Current $1,000 Reduced
29 CFR 1926.501(b)(13):   Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502.      a)  Worksite, Exterior - Employees were not provided with fall protection while installing plywood sheathing to the roof of a two story residential home.  Employees were exposed to a fall of approximately 35ft to the ground below; on or about 08/28/12.    b)  Worksite, Interior, First Floor - Employees were walking and working around a floor opening into the basement.  Employees were exposed to falling into the opening approximately 8ft to the ground below; on or about 8/28/12.    c)  Worksite, Interior, Second Floor - Employees were walking and working around a floor opening into the first floor of the home.  Employees were exposed to falling approximately 12ft to the ground below; on or about 8/28/12.      Note:  In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2800

1926.1053 B04

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 7, 2012
Abate by
Sep 10, 2012
Penalty
Initial $2,000 · Current $750 Reduced
29 CFR 1926.1053(b)(4):   Ladders were used for purposes other than the purposes for which they were designed:    a)  Worksite, Interior, first floor -  Employees were framing interior walls while standing on two 2x10in planks stacked on top of one another.  The planks were being supported by two 6ft A-Frame ladders; on or about 08/28/12.      Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $750
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336017801.