SOUTH PLAINFIELD, NJ —
OSHA Inspection: EVERLASTING VALVE COMPANY INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EVERLASTING VALVE COMPANY INC. in 108 SOMOGYI COURT, SOUTH PLAINFIELD, NJ 07080 (NAICS 332911). OSHA activity number 336027784.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EVERLASTING VALVE COMPANY INC.
- Site address
- 108 SOMOGYI COURT
- City
- SOUTH PLAINFIELD
- State
- NJ
- ZIP
- 07080
- Mailing
- 108 SOMOGYI COURT, SOUTH PLAINFIELD, NJ 07080
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332911
- Employees
- 30
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.215 A01
- Issued
- Oct 15, 2012
- Abate by
- Nov 5, 2012
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.215(a)(1): Abrasive wheel(s) used on grinding machinery were not used with safety guard(s) a) Everlasting Valve Company, Inc. - South Plainfield, NJ Assembly Area - A tongue guard was not installed on an abrasive wheel bench grinder. Condition observed on 8/29/2012.
Recent events (1)
- — Z (S) $2800
1910.1200 F05
- Issued
- Oct 15, 2012
- Abate by
- Nov 5, 2012
- Penalty
- Initial $2,100 · Current $2,100
General-duty citation text
29 CFR 1910.1200(f)(5): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the identity and appropriate hazard warnings regarding the chemicals contained therein: a) Everlasting Valve Company, Inc. - South Plainfield, NJ Manufacturing Area - Two unlabeled containers with liquid inside were kept on top of a 5 gallon drum of Mobil DTE 24 (4F968) Hydraulic Oil. Condition observed on 8/29/2012.
Recent events (1)
- — Z (S) $2100
1910.178 L06
- Issued
- Oct 15, 2012
- Abate by
- Nov 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation. a) Everlasting Valve Company, Inc. - South Plainfield, NJ site Receiving Area -- Operators of propane powered forklift trucks training certifactions were not certified by the company to include date of the training and the identity of the person(s) performing the training or evaluation. Condition observed on 08/29/2012.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 332911)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336027784.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.