KUNA, ID —
OSHA Inspection: REGATTA ROOFING, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of REGATTA ROOFING, INC. in LOT 11, BLOCK 1 WEST HEARTLAND DRIVE, KUNA, ID 83634 (NAICS 238160). OSHA activity number 336031992.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- REGATTA ROOFING, INC.
- Site address
- LOT 11, BLOCK 1 WEST HEARTLAND DRIVE
- City
- KUNA
- State
- ID
- ZIP
- 83634
- Mailing
- 10050 SENECA DR., BOISE, ID 83709
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 2
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.28 A
- Issued
- Sep 21, 2012
- Abate by
- Sep 25, 2012
- Penalty
- Initial $1,020 · Current $0 Reduced
General-duty citation text
29 CFR 1926.28(a): The employer did not require the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions. a) South side of structure, east and west sides of the gable; On or about August 29, 2012 and at times prior thereto, employees utilizing pneumatic nailers to fasten shingles were not wearing eye protection/safety glasses. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $1020
1926.501 B13
- Issued
- Sep 21, 2012
- Abate by
- Sep 25, 2012
- Penalty
- Initial $3,200 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b). Note: If using these systems was infeasible or created a greater hazard, the employer shall develop and implement a fall protection plan meeting the requirements of paragraph (k) of 1926.502. a) South side of structure, east side of the gable; On or about August 29, 2012 and at times prior thereto, an employee was installing shingles on a steep pitched roof of a residential structure without a means of acceptable fall protection. b) South side of structure, west side of the gable; On or about August 29, 2012 and at times prior thereto, an employee was installing shingles on a steep pitched roof of a residential structure without a means of acceptable fall protection. Note: Abatement certification and documentation ARE required for these items. Regatta Roofing, Inc. was previously cited for a violation of this Occupational Safety and Health standard which was contained in OSHA inspection 479760, Citation 1, Item 1, and was affirmed as a final order on 8/15/2012 with respect to a workplace located at Lot 10, Block 9, Naipa, Boise, ID.
Recent events (2)
- — I (R) $0
- — Z (R) $3200
1926.1053 B01
- Issued
- Sep 21, 2012
- Abate by
- Sep 25, 2012
- Penalty
- Initial $2,400 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) South side of structure, east side of the gable; On or about August 29, 2012 and at times prior thereto, an employee performing roofing work utilized a fiberglass extension ladder that was only extended approximately 2.5 feet above the roof eave for access to/from the roof. b) South side of structure, west side of the gable; On or about August 29, 2012 and at times prior thereto, an employee performing roofing work utilized a fiberglass extension ladder that was not extended above the roof eave for access to/from the roof. Note: Abatement certification and documentation IS required for this item.
Recent events (2)
- — I (R) $0
- — Z (R) $2400
More inspections at Regatta Roofing, INC.
View Regatta Roofing, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336031992.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.