MOSCOW, ID —
OSHA Inspection: NICHOLAS GROGAN
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NICHOLAS GROGAN in 1009 SLONAKER DRIVE, MOSCOW, ID 83843 (NAICS 238170). OSHA activity number 336045380.
Where did this inspection happen?
- Establishment
- NICHOLAS GROGAN
- Site address
- 1009 SLONAKER DRIVE
- City
- MOSCOW
- State
- ID
- ZIP
- 83843
- Mailing
- 1622 18TH STREET, LEWISTON, ID 83501
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.28 A
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $600.00 Reduced
General-duty citation text
29 CFR 1926.28(a): The employer did not require the wearing of appropriate personal protective equipment in all operations where there was an exposure for hazardous conditions or where this part indicates the need for using such equipment to reduce the hazards to employees. a) Back of structure: On or about August 15, 2012, and at times prior thereto, an employee without a hard hat was walking/working under or in close proximity to a Alum-A-Pole pump jack scaffold where siding activities were being performed overhead. b) Back of structure: On or about August 15, 2012, and at times prior thereto, employees did not don protective safety glasses while utilzing a pneumatic nail gun. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $1200.00
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems. (a) Back of the structure: On or about August 15, 2012, an employee was observed on a low slope roof involved in siding activities without any means of fall protection and exposed to a fall hazards on this multi story residential job. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $1200
- — Z (S) $1200
1926.503 A02 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee had been trained, as necessary, by a competent person in the use and operation of guardrail systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used: a) Back of Structure: On or about August 15, 2012, and times prior thereto, the employer did not provide training and/or instructions employees to ensure appropriate measures were taken to minimize and/or eliminate potential fall hazards prior to starting work activity. Note) Abatement certification IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. (a) Back of the structure; On or about August 15, 2012, and at times prior thereto, an employee was performing siding work from a Alum-A-Pole pump jack scaffold without a means of fall protection. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $1200
1926.454 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) Back of the structure; On or about August 15, 2012, and at times prior thereto, two employees performing siding work from a Alum-A-Pole pump jack scaffold demonstrated a lack of understanding and recognition of the potential hazards associated with deficiencies including but not limited to, inadequate/missing guardrails and/or end-rails, inadequate bracing and platforms. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238170)
CLINTON, MO—2026-07-14
TORCHYLO BUILDERS, LLC.
HIGH POINT, NC—2026-07-14
161545 - RHP SIDING LLC
HIGH POINT, NC—2026-07-14
161544 - TRIAD SIDING OF THOMASVILLE INCORPORATED
OXFORD, OH—2026-07-13
R&R SIDING LLC
WINSTON SALEM, NC—2026-07-10
161522 - MS SIDING LLC
More inspections in ID
BOISE, ID—2026-07-16
RAYMOND MANAGEMENT COMPANY
MERIDIAN, ID—2026-07-15
TRIPLE R CONSTRUCTION LLC
MERIDIAN, ID—2026-07-15
MIRZON CONSTRUCTION LLC
MERIDIAN, ID—2026-07-15
EASTER SEALS - GOODWILL NORTHERN ROCKY MOUNTAINS
NAMPA, ID—2026-07-15
ELITE STEEL ERECTORS, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336045380.