SUNRISE, FL —
OSHA Inspection: M & S CUSTOM DESIGN AND SERVICES, CORP.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of M & S CUSTOM DESIGN AND SERVICES, CORP. in 10318 NW 55TH STREET, SUNRISE, FL 33351 (NAICS 238350). OSHA activity number 336049218.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- M & S CUSTOM DESIGN AND SERVICES, CORP.
- Site address
- 10318 NW 55TH STREET
- City
- SUNRISE
- State
- FL
- ZIP
- 33351
- Mailing
- 10318 NW 55TH STREET, SUNRISE, FL 33351
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 6
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.213 D01
- Issued
- Oct 30, 2012
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: In the production area of M & S Custom Design and Services, Corp. located at 10318 NW 5th Street in Sunrise, Florida: A table saw being used by an employee performing wood working operations did not have a hood to completely enclose the portion of the blade above the table and above the material being cut, on or about August 30, 2012.
Recent events (2)
- — Z (S) $2800
- — I (S) $1400
1910.242 A
- Issued
- Oct 30, 2012
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.242(a): Hand and portable powered tools or equipment were not kept in safe condition: a) In the production area of M & S Custom Design and Services, Corp. located at 10318 NW 5th Street in Sunrise, Florida: A Router was not kept in a safe condition and had the power cord damaged or severed and repaired then covered with masking tape, on or about August 30, 2012. b) In the production area of M & S Custom Design and Services, Corp. located at 10318 NW 5th Street in Sunrise, Florida: A Miter Saw was not kept in a safe condition and had the power cord damaged and repaired then covered with masking tape, on or about August 30, 2012.
Recent events (2)
- — Z (S) $1600
- — I (S) $800
1910.305 B02
- Issued
- Oct 30, 2012
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.305(b)(2): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: In the production area of M & S Custom Design and Services, Corp. located at 10318 NW 5th Street in Sunrise, Florida: The cover on the electrical box on an air compressor was not in place having the energized wiring and components exposed creating a potential electrocution hazard for employees, on or about August 30, 2012.
Recent events (2)
- — Z (S) $2000
- — I (S) $1000
1910.305 G01 IV A
- Issued
- Oct 30, 2012
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: In the production area of M & S Custom Design and Services, Corp. located at 10318 NW 5th Street in Sunrise, Florida: An electrical flexible extension cord powering tools was used as a substitute for fixed wiring of a structure, on or about August 30, 2012.
Recent events (2)
- — Z (S) $1600
- — I (S) $800
1910.305 G02 II
- Issued
- Oct 30, 2012
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: In the production area of M & S Custom Design and Services, Corp. located at 10318 NW 5th Street in Sunrise, Florida: An electrical flexible extension cord powering tools was not used in a continuous length where the outer sheath and insulation were compromised and covered with masking tape, on or about August 30, 2012.
Recent events (2)
- — Z (S) $1600
- — I (S) $800
1910.305 G02 III
- Issued
- Oct 30, 2012
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: In the production area of M & S Custom Design and Services, Corp. located at 10318 NW 5th Street in Sunrise, Florida: A flexible cord supplying power to an air compressor was not connected to the fitting on the electrical box to provide it with strain relief, on or about August 30, 2012.
Recent events (2)
- — Z (S) $1600
- — I (S) $800
More inspections at M & S Custom Design and Services, Corp.
View M & S Custom Design and Services, Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 238350)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336049218.