JAMESTOWN, NY —
OSHA Inspection: PRODUCTO CORPORATION, RING DIVISION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PRODUCTO CORPORATION, RING DIVISION in 2980 TURNER ROAD, JAMESTOWN, NY 14701 (NAICS 333514). OSHA activity number 336055595.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PRODUCTO CORPORATION, RING DIVISION
- Site address
- 2980 TURNER ROAD
- City
- JAMESTOWN
- State
- NY
- ZIP
- 14701
- Mailing
- 2980 TURNER ROAD, JAMESTOWN, NY 14701
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333514
- Employees
- 90
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.147 C04 I
- Issued
- Sep 26, 2012
- Abate by
- Oct 26, 2012
- Penalty
- Initial $3,825 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about 08/29/12, in the establishment, Employer did not develop and document machine-specific Lockout/Tagout(LOTO) procedures for machines with more than one energy source such as, but not limited to: CNC lathes(Swiss Turns, Star SR32, Citizen/Cincom Citizen), Glass Bead Blaster and Jig Grinder. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $3000
- — Z (S) $3825
1910.147 C06 I
- Issued
- Sep 26, 2012
- Abate by
- Oct 26, 2012
- Penalty
- Initial $3,825 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) On or about 08/29/12, in the establishment, Employer did not conduct annual periodic inspections of their Lockout/Tagout(LOTO) procedures to evaluate their energy control program's accuracy and authorized employees proficiency in the application of LOTO procedures. Employees regularly performed maintenance/servicing on machines such as, but not limited to: CNC lathes, CNC Mills, Jig Grinder, EDM Drill and Glass Bead Blaster. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $3825
1910.147 C06 II
- Issued
- Sep 26, 2012
- Abate by
- Oct 26, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: a) On or about 08/29/12, in the establishment, Employer did not have certifications showing that the lockout/tagout procedures had been inspected by an authorized employee at least annually. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 F03 I
- Issued
- Sep 26, 2012
- Abate by
- Oct 26, 2012
- Penalty
- Initial $3,825 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(f)(3)(i): A procedure was not utilized to afford the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device when servicing and/or maintenance was performed by a crew, craft, department or other group: a) On or about 09/20/12, in the production area, two maintenance employees did not utilize a group lockout/tagout procedure while they were repairing a Citizens CNC lathe. Only one lock was applied on the machine's electrical main power. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $3825
1910.215 A04
- Issued
- Sep 26, 2012
- Penalty
- Initial $2,295 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a) On or about 08/29/12, in the production areas, a Standard Electrical Tool Co, Type 10BA 1HP Bench Grinder's Workrest was adjusted to 1/2 inch. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1500
- — Z (S) $2295
1910.215 B09
- Issued
- Sep 26, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) On or about 08/29/12, in the production areas, a Standard Electrical Tool Co, Type 10BA 1HP Bench Grinder's tongue guard was adjusted to 5/8 inch. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- Sep 26, 2012
- Abate by
- Oct 26, 2012
- Penalty
- Initial $2,295 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) On or about 08/29/12, in the production areas, metal receptacle boxes were used on the end of drop cords instead of being mounted in place as required by the National Electrical Code(NEC). Metal receptacle boxes energized machines such as, but not limited to: Microscopes, Electronic Height Gages, Belt Sander and Parker Majestic Surface Grinding. b) On or about 08/29/12, in the production areas, a metal receptacle box used on the end of a drop cord to energize a Ebbco package Chiller, Model EDM-PC 3300L/EDM Drill CT500F, #383 was not mounted in place. This metal receptacle box showed signs of deterioration/corrosion and it was not appropriate for the specific use and environment. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1500
- — Z (S) $2295
1910.305 B01 II
- Issued
- Sep 26, 2012
- Penalty
- Initial $2,295 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) On or about 08/29/12, in the production areas, two metal receptacles used to energize the Z-Mike by Beta LaserMike, Bench Mike 4025G, had missing knockouts. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (S) $2295
1910.334 A02 II
- Issued
- Sep 26, 2012
- Penalty
- Initial $2,295 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: a) On or about 08/29/12, in the production area, the outer sheath of the cord energizing Ebbco Package Chiller, Model No EDM-PC 3300 L, Edm Drill CT 500F, was damaged and exposing electrical conductors. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1500
- — Z (S) $2295
1910.212 B
- Issued
- Sep 26, 2012
- Abate by
- Oct 26, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a) On or about 08/29/12, in the production areas, a Standard Electrical Tool Co, Type 10BA 1HP Bench Grinder was not anchored to floor. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 333514)