THOMSON, GA —
OSHA Inspection: TWO STATE CONSTRUCTION COMPANY, INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of TWO STATE CONSTRUCTION COMPANY, INC. in 2292 WASHINGTON ROAD PO DRAWER 239, THOMSON, GA 30824 (NAICS 332999). OSHA activity number 336060983.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TWO STATE CONSTRUCTION COMPANY, INC.
- Site address
- 2292 WASHINGTON ROAD PO DRAWER 239
- City
- THOMSON
- State
- GA
- ZIP
- 30824
- Mailing
- 2292 WASHINGTON ROAD PO DRAWER 239, THOMSON, GA 30824
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 121
- Ownership type
- A
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 30, 2012
- Abate by
- Nov 21, 2012
- Penalty
- Initial $6,300 · Current $4,900 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees. Employees were exposed to overhead and crush hazards as the employer did not ensure lower hung cranes were installed and used per the ANSI/ASME B30.11-2004 requirements. The following deficiencies were found and did not meet the requirements: 1 - Initial inspection Section 11-2.1.1- Employees were exposed to crush hazards as the employer did not ensure initial inspections were made to the 5 ton (serial #147132PF1) after it had been modified and installed at the workplace. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $4900
- — Z (S) $6300
1910.37 B06
- Issued
- Oct 30, 2012
- Abate by
- Nov 21, 2012
- Penalty
- Initial $4,500 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color. On or about 8/30/12, in the metal fabrication area, where employees worked night shift, the employer did not ensure emergency exit signs were illuminated. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $2500
- — Z (S) $4500
1910.179 J02
- Issued
- Oct 30, 2012
- Abate by
- Dec 13, 2012
- Penalty
- Initial $6,300 · Current $3,150 Reduced
General-duty citation text
29 CFR 1910.179(j)(2): The items listed in subparagraphs (j)(2)(i)-(vii) were not inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, and all deficiencies were not carefully examined and a determination made as to whether they constituted a safety hazard. On or about or about 8/30/12, employees were expoed to crush hazards as the employer did not ensure frequent crane inspections were made to cranes including the following cranes: 1 - 5 ton Kone Crane Serial #43097-8612 last annual inspection 2/15/2011 (480 volt) revealed required corrections were necessary hook latch damaged, spring broken, wire rope badly kinked, rope guide worn, follower rollers damaged, pendant station damaged, flat ribbon cables pulled out of junction box, Hoist low and high speed contactors burned out, minor wear on trolley pinion gear needs monitoring 2 - 2 ton Shaw Box Serial #32-93261 - last annual inspection 2/15/2011 (480 volt) revealed multiple broken lines in rope & needed replacement, too much rope on drum and needs shortening to proper length, pendant control cable pulled out of trolley J-box and is need of repair, Needed: replace trolley due to it wasnt made for hoist 3 - 3 ton Cleveland Tramrail Serial #Not Visible last annual inspection 7/15/2011 (460 volt) revealed capacity not labeled on both sides of bridge 4 - 3 ton Cleveland Tramrail Serial #EC3C.113.CW last annual inspection 7/15/2011 (460 volt) revealed capacity not labeled on both sides of bridge In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (O) $3150
- — Z (S) $6300
1910.179 J03
- Issued
- Oct 30, 2012
- Abate by
- Nov 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(j)(3): Complete inspections of the crane was not being performed at intervals as generally defined in paragraph (j)(1)(ii)(b) of this section: On or about 8/30/12, at the Thomson facility, the employer did not ensure periodic inspections of cranes in use at the facility were made. Instances include: 1 - 5 ton Kone Crane Serial #43097-8612 last annual inspection 2/15/2011 (480 volt) revealed required corrections were necessary hook latch damaged, spring broken, wire rope badly kinked, rope guide worn, follower rollers damaged, pendant station damaged, flat ribbon cables pulled out of junction box, Hoist low and high speed contactors burned out, minor wear on trolley pinion gear needs monitoring 2 - 2 ton Shaw Box Serial #32-93261 - last annual inspection 2/15/2011 (480 volt) revealed multiple broken lines in rope & needed replacement, too much rope on drum and needs shortening to proper length, pendant control cable pulled out of trolley J-box and is need of repair, Needed: replace trolley due to it wasnt made for hoist 3 - 3 ton Cleveland Tramrail Serial #Not Visible last annual inspection 7/15/2011 (460 volt) revealed capacity not labeled on both sides of bridge 4 - 3 ton Cleveland Tramrail Serial #EC3C.113.CW last annual inspection 7/15/2011 (460 volt) revealed capacity not labeled on both sides of bridge In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.252 B02 III
- Issued
- Oct 30, 2012
- Abate by
- Nov 21, 2012
- Penalty
- Initial $4,500 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields. On or about 8/30/12, in the metal fabrication area, employees were exposed to eye hazards as the employer does not require welding screens to be used in the metal fabrication areas to shield other employees working in close proximity to the area where welding is occurring. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $2500
- — Z (S) $4500
1910.157 E03
- Issued
- Oct 30, 2012
- Abate by
- Nov 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check. On or about 8/30/12, at the Thomson facility, the employer did not ensure all fire extinguishers underwent an annual inspeciton. The fire extinguisher located in themetal fab shop area was last inspected in June 2011. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at TWO State Construction Company, INC.
View TWO State Construction Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336060983.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.