SHERBURNE, NY —
OSHA Inspection: ALBERTINA PROPERTIES, LLC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ALBERTINA PROPERTIES, LLC. in 64 N. MAIN STREET, SHERBURNE, NY 13460 (NAICS 236118). OSHA activity number 336064183.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALBERTINA PROPERTIES, LLC.
- Site address
- 64 N. MAIN STREET
- City
- SHERBURNE
- State
- NY
- ZIP
- 13460
- Mailing
- P.O. BOX 176, SHERBURNE, NY 13460
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 5
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.403 B02
- Issued
- Oct 22, 2012
- Penalty
- Initial $2,400 · Current $0 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) First floor, on or about 8-30-12: Employees were operating various power tools, powered through two relocatable power taps (RPTs) that were not being used in accordance with the manufacturers recommendations or as listed and labeled. b) First floor, on or about 8-30-12: Employees were operating various power tools, powered through portable, job made outlet box assembly that was not being used in accordance with the manufacturers recommendations or as listed and labeled.
Recent events (2)
- — I (S) $0
- — Z (S) $2400
1926.404 B01 II
- Issued
- Oct 22, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection: a) Second floor, on or about 8-30-12: Employees were operating various power tools, powered through extension cord plugged into a duplex receptacle that was not protected by a ground fault circuit interrupter (GFCI).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.404 F06
- Issued
- Oct 22, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) First floor, on or about 8-30-12: Employees were operating various power tools, powered through two extension cords that were missing ground pins.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.403 I02 I
- Issued
- Oct 22, 2012
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph: a) First floor, on or about 8-30-12: Employees were working in the immediate area around an uncovered/unprotected electrical panel with exposed live parts.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1926.501 B01
- Issued
- Oct 22, 2012
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) Second floor, on or about 8-30-12: Employees were working immediately adjacent to an open sided floor without fall protection, exposing the employees to a fall hazard of 11 feet 1 inch.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1926.1052 C01 II
- Issued
- Oct 22, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever was less, were not equipped with one stairrail system along each unprotected side or edge: a) First to second floor, on or about 8-30-12: Employees were using a stairway for access without a stair rail, exposing the employees to a fall hazard of 11 feet 1 inch.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 236118)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336064183.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.