OSHA Inspection: SOBRINSKI PAINTING

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SOBRINSKI PAINTING in 411 MARCH STREET, EASTON, PA 18042 (NAICS 238320). OSHA activity number 336084991.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sobrinski Painting — free Get an email when a new federal OSHA severe-injury report for Sobrinski Painting is published. One employer, no account, unsubscribe in one click.
Establishment
SOBRINSKI PAINTING
Site address
411 MARCH STREET
City
EASTON
State
PA
ZIP
18042
Mailing
128 N 11TH STREET, ALLENTOWN, PA 18102
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238320
Employees
30
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 13, 2012
Abate by
Nov 21, 2012
Penalty
Initial $2,800 · Current $1,680 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that an articulation boom aerial lift was driven over a drainage grate that could not support the maximum load.    a)  March Street, Easton PA - On or about August 28, 2012, the operator of a JLG 600AJ articulating boom aerial lift drove the lift over a metal drainage grate which broke under the weight of the lift causing one of the lift's front tires fall into hole causing the lift to strike the wall of a building.    ABATEMENT NOTE:  One feasible and acceptable means of abatement would be to follow ANSI/SIA A92.5-2006 entitled "Boom Supported Elevating Work Platforms," section 7.8 Work Place Inspections: which states, before the aerial platform is used and during use the user shall check the area in which the aerial platform is to be used for possible hazards such as, but not limited to, inadequate surface and support to withstand all load forces imposed by aerial platform in all operating configurations.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1926.416 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 13, 2012
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:    a)  March Street - On or about August 28, 2012, employees operating a JLG 600AJ articulating boom aerial lift maneuvered the lift in a manner that consistently placed parts of the non-insulated aerial lift within 10 feet from the energized 240 Volt power lines running into the building.