ATLANTA, GA —
OSHA Inspection: MADRAS PACKAGING, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MADRAS PACKAGING, LLC in 6220 DUQUESNE DRIVE SW SUITE A, ATLANTA, GA 30336 (NAICS 326199). OSHA activity number 336092788.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MADRAS PACKAGING, LLC
- Site address
- 6220 DUQUESNE DRIVE SW SUITE A
- City
- ATLANTA
- State
- GA
- ZIP
- 30336
- Mailing
- 6220 DUQUESNE DRIVE SW SUITE A, ATLANTA, GA 30336
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 48
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.37 B02
- Issued
- Dec 3, 2012
- Abate by
- Dec 20, 2012
- Penalty
- Initial $2,380 · Current $1,428 Reduced
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": a) At main storage warehouse and production areas- The employer did not mark each exit door exposing the employees to fire hazards.
Recent events (2)
- — I (S) $1428
- — Z (S) $2380
1910.147 C06 I
- Issued
- Dec 3, 2012
- Abate by
- Dec 28, 2012
- Penalty
- Initial $2,975 · Current $1,785 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) At the Plant- The employer did not conduct at least annual periodic inspections to verify that the energy control procedures were adequate and had been properly applied exposing employees to electrocution and amputation hazards.
Recent events (2)
- — I (S) $1785
- — Z (S) $2975
1910.253 B02 II
- Issued
- Dec 3, 2012
- Abate by
- Dec 13, 2012
- Penalty
- Initial $3,570 · Current $2,142 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders were not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: a) At the west side wall of Maintenance Shop- The employer did not secure the standing Oxygen, Argon , Nitrogen and Acetylene compressed gas cylinders located next to supply cabinet; exposing employees to struck by and asphyxiation hazards.
Recent events (2)
- — I (S) $2142
- — Z (S) $3570
1910.253 B04 I
- Issued
- Dec 3, 2012
- Abate by
- Dec 13, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire; or in an acetylene generator compartment. a) At the west wall of the Maintenance Shop- The employer stored Oxygen and Acetylene compressed gas cylinders together exposing employees to explosion and fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G01 II
- Issued
- Dec 3, 2012
- Abate by
- Dec 13, 2012
- Penalty
- Initial $1,785 · Current $1,071 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: a) At the Maintenance Shop- The employer stored lamps, sheathing, ladder, cartoon and metal mesh in front of two disconnect boxes exposing employees performing inspection and maintenance or emergency to electrical hazards.
Recent events (2)
- — I (S) $1071
- — Z (S) $1785
More inspections at Madras Packaging, LLC
View Madras Packaging, LLC's full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336092788.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.