EAST MOLINE, IL —
OSHA Inspection: EAST MOLINE METAL PRODUCTS COMPANY
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of EAST MOLINE METAL PRODUCTS COMPANY in 1201 7TH ST., EAST MOLINE, IL 61244 (NAICS 332322). OSHA activity number 336118591.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EAST MOLINE METAL PRODUCTS COMPANY
- Site address
- 1201 7TH ST.
- City
- EAST MOLINE
- State
- IL
- ZIP
- 61244
- Mailing
- 1201 7TH ST., EAST MOLINE, IL 61244
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 90
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C06 I
- Issued
- Jan 18, 2013
- Abate by
- Feb 14, 2013
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: In the shop, the employer did not conduct an adequate inspection of the energy control procedures.
Recent events (2)
- — I (S) $1750
- — Z (S) $3500
1910.147 C06 II
- Issued
- Jan 18, 2013
- Abate by
- Feb 14, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection: The periodic inspection certification of the energy control procedures for September 7, and March 15, 2012 did not identify the machine or equipment being reviewed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A03 II
- Issued
- Jan 18, 2013
- Abate by
- Feb 14, 2013
- Penalty
- Initial $4,900 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): Employees working near and operating press brakes were exposed to amputation hazards because the Cincinnati 400H press brake, serial number 37303, was not guarded.
Recent events (2)
- — I (S) $2450
- — Z (S) $4900
1910.147 C04 I
- Issued
- Jan 18, 2013
- Abate by
- Mar 14, 2013
- Penalty
- Initial $4,900 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: In the shop, the employer did not require nor enforce the use of hazardous energy control procedures for activities covered by this standard such as, but not necessarily limited to, die changing on the Cincinnati 400H press brake, serial number 37303.
Recent events (2)
- — I (S) $2450
- — Z (S) $4900
1910.147 C04 II
- Issued
- Jan 18, 2013
- Abate by
- Feb 14, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section: The employer's energy control procedures did not specifically identify the equipment to be used, areas to attach the lockout devices, or authorized employee responsibilities during die changes for machines such as, but not limited to the Cincinnati 400H press brake, serial number 37303.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Jan 18, 2013
- Abate by
- Mar 14, 2013
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices: Employees performing set up and maintenance tasks were exposed to amputation hazards because they had not received training that described the equipment to be used in specific applications, areas to attach the lockout devices, source(s) and type(s) of hazardous energy specific to different machines, nor identify authorized user responsibilities.
Recent events (2)
- — I (S) $0
- — Z (S) $3500
More inspections at East Moline Metal Products Company
View East Moline Metal Products Company's full OSHA safety record →
More inspections in this industry (NAICS 332322)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336118591.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.