Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: A & M DRYWALL CONSTRUCTION, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of A & M DRYWALL CONSTRUCTION, INC. in 1634 14TH STREET, NW, WASHINGTON, DC 20009 (NAICS 238310). OSHA activity number 336123591.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A & M Drywall Construction, INC. — free Get an email when a new federal OSHA severe-injury report for A & M Drywall Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1634 14TH STREET, NW
City
WASHINGTON
State
DC
ZIP
20009
Mailing
2613 MORSE LANE, WOODBRIDGE, VA 22192
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
6
Ownership type
A

3 citations on file for this inspection.

1926.552 B02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 19, 2012
Penalty
Initial $3,500 · Current $2,500 Reduced
29 CFR 1926.552(b)(2)(i): Bars on hoistway entrances were not located 2 feet from the hoistway line:    a) East Side of the building on all floors - The bars on the hoistways were located flush against the exterior walls only 11 inches back from the hoistway centerline. Carpenters were observed signalling the hoist car by leaning out of the hoistway opening where the guardrails were installed only 11 inches back from the hoistway centerline exposing the carpenters to struck-by hazards.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3500

1926.552 B05 II

Serious 1 instance 3 exposed
Issued
Nov 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.552(b)(5)(ii):  A 6-foot high enclosure was not provided on the unused sides of the hoist towers at ground level:    a) East Side of the Building  - A 6-foot high enclosure was not provided on the unused sides of the hoist towers at ground level. A mason foreman and laborer were observed standing directly under a material hoist car which was not provided with a 6 ft. ground barrier exposing them to a potential struck by hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1052 C01 I

Other-than-serious 2 instances 2 exposed
Issued
Nov 19, 2012
Penalty
Initial $2,100 · Current $500 Reduced
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:    a) Internal Stair Systems throughout the Building - Stairways were not equipped with at least one handrail. Employees were observed using interior stairs for accessing the various work areas where the stairs were not equipped with a standard handrail. Each stairway Contained 15 to 19 risers exposing the employees slip, trip or fall hazards of 12 feet.    b) Primary Entrance into the Building - Stairways were not equipped with at least one handrail. All employees were observed using the exterior stairs as access into the building, they contained 8 risers exposing them to a 6 foot slip or trip hazard.
Recent events (2)
  • — I (O) $500
  • — Z (S) $2100

View A & M Drywall Construction, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336123591.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.