Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SNF FLOMIN

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SNF FLOMIN in 7500 FM 1405, BAYTOWN, TX 77523 (NAICS 325998). OSHA activity number 336139001.

Watch SNF Flomin — free Get an email when a new federal OSHA severe-injury report for SNF Flomin is published. One employer, no account, unsubscribe in one click.
Establishment
SNF FLOMIN
Site address
7500 FM 1405
City
BAYTOWN
State
TX
ZIP
77523
Mailing
7500 FM 1405, BAYTOWN, TX 77523
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325998
Employees
40
Ownership type
A

13 citations on file for this inspection.

1910.106 B02 VI B

Serious Gravity 1 1 instance 8 exposed
Issued
Penalty
Initial $2550.00 · Current $2550.00
29 CFR 1910.106(b)(2)(vi)(b): Where vent pipe outlets for tanks storing Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 F (37.8 C), are adjacent to buildings or public ways, they were not located so that the vapors are released at a safe point outside of buildings and not less than 12 feet above the adjacent ground level:      This hazard was most recently observed on October 9, 2012 at the SNF Flomin facility located in Baytown, TX, where the employer failed to ensure that relief valve/vent piping discharge is released upward or horizontally, to facilitate dispersion away from ground level and public ways.
Recent events (2)
  • — I (S) $2550
  • — Z (S) $2550

1910.119 D03 I A

Serious Gravity 5 1 instance 8 exposed
Issued
Penalty
Initial $4250.00 · Current $4250.00
29 CFR 1910.119(d)(3)(i)(A): The employer did not complete a compilation of process safety information pertaining to the material of construction of  equipment in the process:       This hazard was most recently observed on October 9, 2012 at the SNF Flomin facility located in Baytown, TX, where the employer failed to complete a compilation of the material of construction for a relief valve that supplies relief to the Allyl Chloride storage/charge tank
Recent events (2)
  • — I (S) $4250
  • — Z (S) $4250

1910.119 D03 II

Serious Gravity 5 2 instances 8 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices:      (a) This hazard was most recently observed on or about October 9, 2012 at the SNF Flomin facility located in Baytown, TX, where the employer failed to comply with RAGAGEP when a discharge line from a relief valve located on the Allyl Chloride storage/charge tank had potential to relieve to an unsafe location when a pressure vessel was the source of potential source of the potential relieving event. (An example of a RAGAGEP for discharging pressure vessels to safe locations is the BPVC, Section UG-135(f))       (b) This hazard was most recently observed on or about October 9, 2012 at the SNF Flomin facility located in Baytown, TX, where the employer failed to comply with RAGAGEP when a relief valve located on the Allyl Chloride storage/charge tank was not designed to handle two phase flow and was properly sized. (An example of a RAGAGEP for sizing pressure relief devices is API RP 520)
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.119 E03 I

Other-than-serious 3 instances 8 exposed
Issued
Penalty
Initial $5000.00 · Current $5000.00
29 CFR 1910.119(e)(3)(i): The Process Hazard Analysis did not address the hazards of the process:        This hazard was most recently observed on October 9, 2012 at the SNF Flomin facility located in Baytown, TX, where the employer failed to identify and evaluate the hazards associated with operating powered industrial trucks in close proximity to process equipment.
Recent events (2)
  • — I (O) $5000
  • — Z (S) $5000

1910.119 E05

Serious Gravity 10 1 instance 8 exposed
Issued
Penalty
Initial $7000.00 · Current $5000.00 Reduced
29 CFR 1910.119(e)(5): The employer did not assure that PHA recommendations were resolved in a timely manner:    This hazard was most recently observed on or about October 9, 2012 at the SNF Flomin facility located in Baytown, TX, where the employer failed to correct facility citing hazards identified in the 2005-2006 Process Hazard Analysis revalidation
Recent events (2)
  • — I (S) $5000
  • — Z (S) $7000

1910.119 E06

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.119(e)(6): At least every five (5) years after the completion of the initial process hazard analysis, the process hazard analysis was not updated and revalidated by a team meeting the requirements in paragraph (e)(4) of this section, to assure that the process hazard analysis is consistent with the current process:                                                                    -In the Alternative-    29 CFR 1910.119(e)(7): Employer did not retain process hazards analyses and updates or revalidations for each process covered by this section, as well as the documented resolution of recommendations described in paragraph (e)(5) of this section for the life of the process:      This hazard was most recently observed on or about October 9, 2012 at the SNF Flomin facility located in Baytown, TX, where the employer failed to provide the process hazards analysis revalidation for 2011.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.119 G02

Other-than-serious 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $5000.00 · Current $5000.00
29 CFR 1910.119(g)(2): Refresher training. Refresher training was not provided at least every three years, and more often if necessary, to each employee involved in operating a process to assure that the employee understands and adheres to the current operating procedures of the process:      This hazard was most recently observed on or about October 9, 2012 at the SNF Flomin facility located in Baytown, TX, where the employer failed to ensure that operators received refresher training at least every 3 years after their initial training.
Recent events (2)
  • — I (O) $5000
  • — Z (S) $5000

1910.119 G03

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.119(g)(3): Training documentation. The employer did not ascertain that each employee involved in operating a process has received and understood the training required by this paragraph. The employer did not prepare a record which contains the identity of the employee, the date of training, and the means used to verify that the employee understood the training:     This hazard was most recently observed on or about October 9, 2012 at the SNF Flomin facility located in Baytown, TX, where the employer failed to maintain and document that operators received and understood initial training and verify  that the employee understood the training.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.119 J04 I

Serious Gravity 10 2 instances 8 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $5000.00 Reduced
29 CFR 1910.119(j)(4)(i): Inspections and tests shall be performed on process equipment:                                                                - In The Alternative -     29 CFR 1910.119(j)(4)(ii): Inspection and testing procedures did not follow recognized and generally accepted good engineering practices:     (a) This hazard was most recently observed on October 9, 2012 at the SNF Flomin facility located in Baytown, TX, where the employer failed to inspect, test and maintain the safety relief valve on the Allyl Chloride storage\charge tank.      (b) This hazard was most recently observed on October 9, 2012 at the SNF Flomin facility located in Baytown, TX, where the employer failed to inspect, test and maintain Rupture disk throughout the facility.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $7000

1910.119 F04

Serious Gravity 5 3 instances 8 exposed
Issued
Penalty
Initial $4250.00 · Current $4250.00
29 CFR 1910.119(f)(4): The employer did not develop and implement safe work practices to provide for the control of hazards during operations such as lockout/tagout; confined space entry; opening process equipment or piping; and control over entrance into a facility by maintenance, contractor, laboratory, or other support personnel. These safe work practices shall apply to employees and contractor employees:     This hazard was most recently observed on October 9, 2012 at the SNF Flomin facility located in Baytown, TX, where the employer developed, but failed to implement the safe work practice for motorized equipment entering operating units that contain flammable or combustible materials.
Recent events (2)
  • — I (S) $4250
  • — Z (S) $4250

1910.307 C02 I

Serious 5 instances 8 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.307(c)(2)(i): Equipment in hazardous (classified) location(s) was not approved for the ignitable or combustible properties of the specific gas, vapor, dust, or fiber that was or could be present:      (a) This hazard was most recently observed on or about October 9, 2012 at the SNF Flomin facility located in Baytown, TX, where the employer failed ensure that a fan installed next to RX1 was approved for the class of location.      (b) This hazard was most recently observed on or about October 9, 2012 at the SNF Flomin facility located in Baytown, TX, where the employer failed to ensure that a Brother fax/copy machine was approved for the class of location.     (c) ) This hazard was most recently observed on or about October 9, 2012 at the SNF Flomin facility located in Baytown, TX, where the employer failed to ensure that a power strip used to supply power to a brother fax/copy machine was approved for the class of location.      (d) This hazard was most recently observed on or about October 9, 2012 at the SNF Flomin facility located in Baytown, TX, where the employer failed to ensure that an electrical expansion pigtail used to supply power to an industrial fan was approved for the class of location.     (e) This hazard was most recently observed on October 9, 2012 at the SNF Flomin facility located in Baytown, TX, where the employer failed to ensure that powered industrial trucks being operated in the process unit were approved for the class of location.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.119 K01

Serious Gravity 5 3 instances 8 exposed
Issued
Penalty
Initial $3400.00 · Current $0.00 Reduced
29 CFR 1910.119(k)(1): The employer did not issue a hot work permit for hot work operations conducted on or near a covered process:     This hazard was most recently observed on October 9, 2012 at the SNF Flomin facility located in Baytown, TX, where the employer failed to issue a hot work permit for non-intrinsically safe powered industrial trucks operating in close proximity to process equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3400

1910.119 L01

Other-than-serious 1 instance 8 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.119(l)(1): The employer did not establish and implement written procedures to manage changes (except for "replacements in kind") to process chemicals, technology, equipment, and procedures; and, changes to facilities that affect a covered process:     This hazard was most recently observed on October 9, 2012 at the SNF Flomin facility located in Baytown, TX, where the employer failed implement written procedures to manage changes to RX1, when it was determined that the glass lining was damaged.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336139001.