KYLE, TX —
OSHA Inspection: MULLEN ELECTRIC CO.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of MULLEN ELECTRIC CO. in 1670 KOHLER'S CROSSING, KYLE, TX 78640 (NAICS 238210). OSHA activity number 336143193.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MULLEN ELECTRIC CO.
- Site address
- 1670 KOHLER'S CROSSING
- City
- KYLE
- State
- TX
- ZIP
- 78640
- Mailing
- 251 BRITNI LOOP, KYLE, TX 78640
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 1
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.26 C02 VII
- Issued
- Feb 7, 2013
- Abate by
- Feb 8, 2013
- Penalty
- Initial $1,200 · Current $800 Reduced
General-duty citation text
29 CFR 1910.26(c)(2)(vii): Ladders having defects were not marked and taken out of service until repaired. On or about September 04, 2012, an employee was using a Louisville, 40-foot extension ladder that was extended approximately 21 feet to repair the Lithonia ballast, enclosed Low Bay lamp with light bulb. The ladder was missing the rope to disengage the locking mechanism, exposing the employee to the hazard of being struck by the extended ladder. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that ladders having defects are marked and taken out of service until repaired.
Recent events (2)
- — I (S) $800
- — Z (S) $1200
1910.333 C07
- Issued
- Feb 7, 2013
- Abate by
- Feb 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(c)(7): Portable ladders shall have nonconductive side rails if they are used where the employee or the ladder could contact exposed energized parts. On or about September 04, 2012, an employee was working from a 40-foot aluminum extension ladder extended to 21 feet, repairing a Lithonia ballast, enclosed Low Bay lamp with light bulb. The ladder was aluminum and was not equipped with non-conductive side rails, exposing the employee to an electrical shock hazard. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps to ensure that portable ladders will have nonconductive side rails if they are used where the employee or the ladder can come into contact with energized electrical parts.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.333 A02
- Issued
- Feb 7, 2013
- Abate by
- Feb 8, 2013
- Penalty
- Initial $2,800 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.333(a)(2): Where exposed live parts were not deenergized, other safety related work practices were not used to protect employees who could be exposed to the electrical hazards involved. On or about September 04, 2012, an employee was working from a 40-foot, aluminum extension ladder that was extended to 21 feet, repairing a Lithonia ballast, enclosed Low Bay lamp with light bulb. The light switch was in the "on" position and the circuit was not de-energized, exposing the employee to an electrical shock hazard. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that safety related work practices are used to protect employees who are exposed to the electrical hazards involved.
Recent events (2)
- — I (S) $2000
- — Z (S) $2800
1910.333 C02
- Issued
- Feb 7, 2013
- Abate by
- Feb 8, 2013
- Penalty
- Initial $2,800 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.333(c)(2): The employer did not ensure that only qualified persons were working on energized circuits and that qualified persons were familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools. On or about September 04, 2012, an unqualified employee was working from a 40-foot, aluminum extension ladder extended to 21 feet, repairing a Lithonia ballast, enclosed Low Bay lamp with light bulb. The employee was not qualified to work on the 480-Volt light that was energized, exposing the employee to an electrical shock hazard. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that only qualified persons are working on energized circuits and that they are familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools.
Recent events (2)
- — I (S) $2000
- — Z (S) $2800
More inspections in this industry (NAICS 238210)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336143193.