Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ENCANA OIL AND GAS USA

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of ENCANA OIL AND GAS USA in DAVIS 1A, 1B, 1C 9H, FORT LUPTON, CO 80621 (NAICS 221210). OSHA activity number 336144191.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Encana OIL and GAS USA — free Get an email when a new federal OSHA severe-injury report for Encana OIL and GAS USA is published. One employer, no account, unsubscribe in one click.
Site address
DAVIS 1A, 1B, 1C 9H
City
FORT LUPTON
State
CO
ZIP
80621
Mailing
370 17TH ST. SUITE 1700, DENVER, CO 80202
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221210
Employees
300
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 4 exposed
Issued
Feb 14, 2013
Abate by
Apr 2, 2013
Penalty
Initial $7,000 · Current $7,000
Section (5)(a)(1) of the Occupational Safety and Health Act of 1970:  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to struck-by hazards due to the inadvertent release of pressurized natural gas:    (a)Encana Oil and Gas USA at Davis 1a, 1b, 1c 9H, Fort Lupton, CO 80621:  On August 15, 2012 the employer did not ensure that employees engaged in connecting a flowline extension to the well head were protected from struck-by hazards associated with pressurized natural gas.  The employer did not have sufficient procedures and controls implemented to effectively ensure the pipeline was de-energized (flowline and riser blown down) before work began that led to a catastrophic release of natural gas.  This condition exposed the employees to a struck-by hazard.    Abatement Note:  Among other methods, one feasible and acceptable method to correct this hazard is to develop and implement specific procedural elements to control hazardous energy in accordance with the American Petroleum Institute (API) recommended practice 74 section 6.3 Lockout/Tagout which states: A lockout/tagout program shall be established to control hazardous energy as follows: (b) Personnel should be trained and disciplined in the  use of this system to prevent unexpected operations of any equipment that stores any type of energy that might inflict injury to personnel.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $7000

View Encana OIL and GAS USA's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336144191.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.