WASHINGTON, DC —
OSHA Inspection: FELLS MASONRY AND CONCRETE, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FELLS MASONRY AND CONCRETE, LLC in 1420 R STREET NW, WASHINGTON, DC 20009 (NAICS 238140). OSHA activity number 336145388.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FELLS MASONRY AND CONCRETE, LLC
- Site address
- 1420 R STREET NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20009
- Mailing
- 522 GOOD HOPE ROAD SE, WASHINGTON, DC 20020
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.100 A
- Issued
- Oct 23, 2012
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) North-West Side of Building - Employees erecting a tubular welded scaffold, were not provided with head protection. Employees were exposed to the possible danger of head injury from falling objects.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.451 B01 I
- Issued
- Oct 23, 2012
- Penalty
- Initial $2,400 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide. a) North-West Side of Building, 3rd Section - A mason was observed working from the third level of a tubular welded frame scaffold which was not fully planked. The employee was exposed to a fall from elevation of greater than 14 feet to the ground below. b) North-East Side of Building, 2nd Section - A mason was observed working from the 2nd level of a tubular welded frame scaffold which was not fully planked. The employee was exposed to a fall from elevation of greater than 13 feet to the ground below. c) North-East Side of Building, 1st Section - A mason was observed working from the 1st level of a tubular welded frame scaffold which was not fully planked. The employee was exposed to a fall from elevation of approximately 6 feet - 8 inches to the ground below.
Recent events (2)
- — I (S) $1200
- — Z (S) $2400
1926.451 G01
- Issued
- Oct 23, 2012
- Abate by
- Oct 24, 2012
- Penalty
- Initial $2,400 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. a) North-East Side of Building, 2nd Level - A mason was observed working from the 2nd level of a tubular welded frame scaffold which was not equipped with guardrails or other means of fall protection on all open sides. This condition exposed employees to a fall from elevation of greater than 13 feet to the ground below. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $2400
1926.451 E01
- Issued
- Oct 23, 2012
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access. a) North-West Side of Building - Masons were observed using the cross braces for access and egress to their platform on a tubular welded frame scaffold. This condition exposed employees to a fall from elevation of greater than 20 feet to the ground below. b) North-East Side of Building - A mason was observed using the horizontal members of the tubular welded frame scaffold for egress. This condition exposed employees to a fall from elevation of greater than 13 feet to the ground below.