JACKSONVILLE, FL —
OSHA Inspection: COLORS CONSTRUCTION INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of COLORS CONSTRUCTION INC. in 3733 VALVERDE CIRCLE, JACKSONVILLE, FL 32224 (NAICS 238130). OSHA activity number 336148382.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COLORS CONSTRUCTION INC.
- Site address
- 3733 VALVERDE CIRCLE
- City
- JACKSONVILLE
- State
- FL
- ZIP
- 32224
- Mailing
- 5002 ISLAND CLUB DR, TAMARAC, FL 33319
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 6
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.100 A
- Issued
- Sep 27, 2012
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: a. On or about August 30, 2012, employees cutting wood on the ground and throwing wood pieces to the carpenters doing the roof sheathing of a residential house were not wearing hardhats, exposing themselves to head injuries.
Recent events (1)
- — Z (S) $1600
1926.501 B13
- Issued
- Sep 27, 2012
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502. a. On or about August 30, 2012, two employees installing roof sheathing on a 7:12 pitch residential roof were not being protected by a guardrail system, safety net or personal fall arrest system, exposing themselves to a 10.5 feet fall hazard.
Recent events (1)
- — Z (S) $2400
1926.1053 B01
- Issued
- Sep 27, 2012
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On or about August 30, 2012, in the North West side of the residential roof, an employee doing roof sheathing on a 7:12 pitch roof set up the Louisville 20-foot fiberglass extension ladder at 2 feet above the landing surface, exposing himself to a 10.5 feet fall hazard. b. On or about August 30, 2012, in the South West side of the residential roof, an employee doing roof sheathing on a 7:12 pitch roof set up the Werner 24-foot aluminum extension ladder at 1 ? feet above the landing surface, exposing himself to a 10.5 feet fall hazard.
Recent events (1)
- — Z (S) $1200
More inspections at Colors Construction INC.
View Colors Construction INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336148382.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.