Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RAINSVILLE TECHNOLOGY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RAINSVILLE TECHNOLOGY, INC. in 189 RTI DRIVE, RAINSVILLE, AL 35986 (NAICS 326199). OSHA activity number 336176987.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rainsville Technology, INC. — free Get an email when a new federal OSHA severe-injury report for Rainsville Technology, INC. is published. One employer, no account, unsubscribe in one click.
Site address
189 RTI DRIVE
City
RAINSVILLE
State
AL
ZIP
35986
Mailing
189 RTI DRIVE, RAINSVILLE, AL 35986
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
457
Ownership type
A

5 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 16, 2012
Abate by
Oct 23, 2012
Penalty
Initial $3,750 · Current $2,250 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:      (a) On or about 09/04/12 - Maintenance Shop, a Sharp milling & drilling machine did not have a chuck or spindle guard installed.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $3750

1910.215 B09

Serious Gravity 5 2 instances 3 exposed
Issued
Oct 16, 2012
Penalty
Initial $3,000 · Current $1,800 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one-fourth inch:      (a) On or about 09/04/12 - Maintenance Shop, the tongue guards on the pedestal-mounted abrasive grinder were not adjusted to at least one-fourth inch.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3000

1910.242 B

Serious Gravity 1 5 instances 3 exposed
Issued
Oct 16, 2012
Abate by
Oct 23, 2012
Penalty
Initial $2,250 · Current $1,350 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:      (a) On or about 09/04/12 - A-5, A-7, E-2 and F-1 Injection Molding Machines, compressed air was used with an output of 40 to 70 p.s.i. to clean out hoppers.
Recent events (2)
  • — I (S) $1350
  • — Z (S) $2250

1910.303 G02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 16, 2012
Abate by
Oct 23, 2012
Penalty
Initial $3,750 · Current $2,250 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):      (a) On or about 09/04/12 - A-7 Injection Molding Machine, a 110-volt electrical fan switch/outlet box was not closed.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $3750

1910.303 B02

Serious Gravity 5 5 instances 2 exposed
Issued
Oct 16, 2012
Abate by
Oct 23, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:      (a) On or about 09/04/12 - A-7 Injection Molding Machine, a 110-volt electrical fan switch/outlet box was not listed or rated for use.    (b) On or about 09/04/12 - Injection Molding Machines, several 110-volt electrical outlet boxes were not listed or rated for use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Rainsville Technology, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336176987.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.