Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CARUSONE CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CARUSONE CONSTRUCTION in E WESTMORELAND ST & MERCER ST, PHILADELPHIA, PA 19134 (NAICS 237110). OSHA activity number 336188180.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Carusone Construction — free Get an email when a new federal OSHA severe-injury report for Carusone Construction is published. One employer, no account, unsubscribe in one click.
Site address
E WESTMORELAND ST & MERCER ST
City
PHILADELPHIA
State
PA
ZIP
19134
Mailing
3245 S 74TH ST, PHILADELPHIA, PA 19153
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
25
Ownership type
A

4 citations on file for this inspection.

1926.651 A

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 11, 2013
Abate by
Feb 15, 2013
Penalty
Initial $2,000 · Current $600 Reduced
29 CFR 1926.651(a):     All surface encumbrances that were located so as to create a hazard to employees were not removed or supported, as necessary, to safeguard employees.      a) Jobsite: E Westmoreland St. and Mercer St., Philadelphia, PA - On or about 8/30/12, the underground utility lines were not removed or supported as necessary to safeguard employees working inside the excavation measuring approximately 8 feet in depth, 15 feet in length, and  11 feet in width. Employees were installing an inlet and making other sewer connections.
Recent events (2)
  • — I (S) $600
  • — Z (S) $2000

1926.651 C02

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 11, 2013
Abate by
Feb 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.651(c)(2):     A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees.    a) Jobsite: E Westmoreland St. and Mercer St., Philadelphia, PA - On or about 8/30/12, a stairway, ladder, ramp, or other safe means of access was not provided to employees working inside the excavation measuring approximately 8 feet in depth, 15 feet in length, and  11 feet in width. Employees were installing an inlet and making other sewer connections.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.652 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 11, 2013
Abate by
Feb 15, 2013
Penalty
Initial $2,000 · Current $1,800 Reduced
29 CFR 1926.652(a)(1):     Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c).     a) Jobsite: E Westmoreland St. and Mercer St., Philadelphia, PA - On or about 8/30/12, a protective system was not used to protect employees from cave-in hazards while working in the excavation measuring approximately 8 feet in depth, 15 feet in length, and  11 feet in width. Employees were installing an inlet and making other sewer connections.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $2000

1926.21 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 11, 2013
Abate by
Mar 31, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.21(b)(2):     The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:    a) Jobsite: E Westmoreland St. and Mercer St., Philadelphia, PA - On or about 8/30/12, Carusone Construction did not instruct each employee to avoid hazards associated with excavation work, to control or eliminate such hazards.  Employees were installing an inlet and making other sewer connections inside the excavation measuring approximately 8 feet in depth, 15  feet in length, and 11 feet in width.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Carusone Construction's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336188180.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.