Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: R-HIVE HOLDINGS, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of R-HIVE HOLDINGS, LLC in 3303 66TH STREET, KENOSHA, WI 53144 (NAICS 331513). OSHA activity number 336195581.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R-Hive Holdings, LLC — free Get an email when a new federal OSHA severe-injury report for R-Hive Holdings, LLC is published. One employer, no account, unsubscribe in one click.
Site address
3303 66TH STREET
City
KENOSHA
State
WI
ZIP
53144
Mailing
3303 66TH STREET, KENOSHA, WI 53142
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331513
Employees
91
Ownership type
A

14 citations on file for this inspection.

1910.23 A08 II

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 1, 2012
Abate by
Nov 16, 2012
Penalty
Initial $2,310 · Current $2,310
29 CFR 1910.23(a)(8)(ii):     Every floor hole into which persons can accidentally walk was not protected by either a removable standard railing or an attendant.     (a) In the cleaning building adjacent to the blast cabinet, a floor hole 50 inches wide by 94 inches in length by 37 inches deep was unguarded and unattended, exposing employees to a fall hazard.
Recent events (2)
  • — I (S) $2310
  • — Z (S) $2310

1910.23 C01

Serious Gravity 5 3 instances 3 exposed
Issued
Nov 1, 2012
Abate by
Nov 16, 2012
Penalty
Initial $3,080 · Current $0 Reduced
29 CFR 1910.23(c)(1):     Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:    (a) In the cleaning room above the blast cabinet, open-sided platforms without continuous standard guard railings exposed employees to approximate 120 inch fall hazards when working from that level.     (b)  In the cleaning room adjacent to the blast cabinet, an open-sided landing platform over the pit did not have standard guard railings that would protect employees from 51 inch fall hazards.     (c)  In the cleaning room above the break room and/or restrooms, an open-sided mezzanine did not have standard guard railings that would protect the employees from approximate 114 inch fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3080

1910.23 D01

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 1, 2012
Abate by
Nov 16, 2012
Penalty
Initial $2,310 · Current $0 Reduced
29 CFR 1910.23(d)(1):     Every flight of stairs having four or more risers was not equipped with standard stair railings or standard handrails as specified in paragraphs (d)(1)(i) through (v) of this section, the width of the stair to be measured clear of all obstructions except handrails:    (a)  In the melting area, the stairs containing four risers leading to the furnace charging area was not equipped with a standard handrail on the open side. Employees were exposed to fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2310

1910.215 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 1, 2012
Penalty
Initial $3,080 · Current $1,540 Reduced
29 CFR 1910.215(a)(4):     Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    (a) In the pattern repair room, the left side work rest on the pedestal grinder (make/model unknown) was positioned 3/8 inches from the abrasive wheel. Employees were exposed to entanglement hazards.
Recent events (2)
  • — I (S) $1540
  • — Z (S) $3080

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 1, 2012
Abate by
Nov 16, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9):     The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    (a) In the pattern repair room, the right side tongue guard on the pedestal grinder (make/model unknown) was not in place and less than 1/4 inches from the abrasive wheel. Employees were exposed to entanglement hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 4 instances 5 exposed
Issued
Nov 1, 2012
Abate by
Nov 8, 2012
Penalty
Initial $3,850 · Current $1,925 Reduced
29 CFR 1910.305(b)(1)(ii):     Unused openings in boxes, cabinets, or fittings were not effectively closed:    (a) In the core room in the main foundry building, the electrical cabinet housing the switch for the lights had electrical tape covering an unused opening. Employees were exposed to energized wires.      (b)  In the main foundry building, a metallic utility box powering the disc sander had an unused opening unguarded, exposing employees to energized wires.     (c)  In the main foundry building, a metallic utility box powering the Dry Rod Electrode Stabilizing Oven had an unused opening unguarded, exposing employees to energized wires.     (d)  In the main foundry building, the electrical panel for the overhead roll door had an unused opening unguarded, exposing employees to energized wires.
Recent events (2)
  • — I (S) $1925
  • — Z (S) $3850

1910.147 C06 I

Repeat Gravity 5 1 instance 2 exposed
Issued
Nov 1, 2012
Abate by
Nov 26, 2012
Penalty
Initial $7,700 · Current $3,850 Reduced
29 CFR 1910.147(c)(6)(i):     The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    (a)  The employer did not ensure a periodic inspection of the energy control procedures was conducted at least annually for pieces of equipment such as but not limited to the air compressor(s), roll-over machine(s), and band saw(s). Employees were exposed to struck-by and/or entanglement hazards.     R-HIVE HOLDINGS LLC DBA KENOSHA STEEL CASTINGS, INC WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD [29 CFR 1910.147(c)(6)(i)], WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 311402473, CITATION NUMBER 1, ITEM NUMBER 2 AND WAS AFFIRMED AS A FINAL ORDER ON APRIL 30, 2009, WITH RESPECT TO A WORKPLACE LOCATED AT 3303 66TH STREET, KENOSHA, WISCONSIN.
Recent events (2)
  • — I (R) $3850
  • — Z (R) $7700

1910.27 F

Other-than-serious 1 instance 3 exposed
Issued
Nov 1, 2012
Abate by
Nov 26, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.27(f):     Ladders were not maintained in a safe condition or inspected regularly:    (a)  The employer did not develop and implement an inspection program for fixed ladders. Fixed ladder(s) were not maintained in a safe condition in that the fixed ladder for the blast cabinet had a bent rung.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.146 C01

Other-than-serious 1 instance 2 exposed
Issued
Nov 1, 2012
Abate by
Nov 26, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(1):     The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces:    (a)  The employer did not ensure the facility was evaluated to determine if any permit-required confined spaces were present onsite.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.146 C02

Other-than-serious 1 instance 2 exposed
Issued
Nov 1, 2012
Abate by
Nov 26, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(2):     The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces:    (a) The employer did not ensure permit-required confined spaces were labeled appropriately with signs and/or other means to identify their existence.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.176 B

Other-than-serious 1 instance 1 exposed
Issued
Nov 1, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.176(b):     Storage of material created a hazard:    (a)  In the Main Foundry Building, the storage racks containing sleeves had damaged upright frame members.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01

Other-than-serious 1 instance 1 exposed
Issued
Nov 1, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1):     Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    (a)  In the Core Room, working space around the electrical panel was blocked by items such as a microwave, cooler, fan, and cores.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 A02 I

Other-than-serious 1 instance 1 exposed
Issued
Nov 1, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(a)(2)(i):     Temporary electrical power and lighting installation(s) 600 volts, nominal, or less were used in prohibited manners:  Note:  Temporary electrical power and lighting installation(s) may only be used as specified by 1910.305(a)(2)(i)(A) through 1910.305(a)(2)(i)(C).    (a)  In the Core Room, temporary wiring was used in place of permanent wiring to power items such as but not limited to the GE Microwave.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G02 III

Other-than-serious 1 instance 1 exposed
Issued
Nov 1, 2012
Abate by
Nov 8, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii):     Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:    (a)  In the Main Foundry Building, the power cord to the pipe threader did not have strain relief in that the cord was pulled from the plug end.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336195581.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.