ALLENPORT, PA —
OSHA Inspection: AMERICAN IRON OXIDE COMPANY DBA AMROX
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AMERICAN IRON OXIDE COMPANY DBA AMROX in 2 WHEELING PITTSBURGH DRIVE, ROUTE 88 SOUTH, ALLENPORT, PA 15142 (NAICS 325131). OSHA activity number 336197199.
Where did this inspection happen?
- Establishment
- AMERICAN IRON OXIDE COMPANY DBA AMROX
- Site address
- 2 WHEELING PITTSBURGH DRIVE, ROUTE 88 SOUTH
- City
- ALLENPORT
- State
- PA
- ZIP
- 15142
- Mailing
- P.O. BOX 299, ALLENPORT, PA 15412
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325131
- Employees
- 33
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.134 C
- Issued
- Sep 27, 2012
- Abate by
- Nov 16, 2012
- Penalty
- Initial $2,100 · Current $1,365 Reduced
General-duty citation text
29 CFR 1910.134(c): The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use: (a) Facility- 2 Wheeling Pittsburgh Drive, Allenport, PA: On or about September 7, 2012, the employer did not develop and implement a written respiratory protection program.
Recent events (2)
- — I (S) $1365
- — Z (S) $2100
1910.134 E01
- Issued
- Sep 27, 2012
- Abate by
- Nov 16, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator before the employee was fit tested or required to use the respirator in the workplace: (a) Facility- 2 Wheeling Pittsburgh Drive, Allenport, PA: On or about September 7, 2012, employees required to wear a half-face cartridge respirator while working with hazardous chemicals were not provided with an initial medical evaluation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F
- Issued
- Sep 27, 2012
- Abate by
- Nov 16, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f): The employee was required to use a respirator without being fit tested with the same make, model, style and size of respirator that was to be used: (a) Facility- 2 Wheeling Pittsburgh Drive, Allenport, PA: On or about September 7, 2012, employees required to wear a half-face cartridge respirator while working in hazardous chemicals were not annually fit tested.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.151 C
- Issued
- Sep 27, 2012
- Abate by
- Oct 19, 2012
- Penalty
- Initial $2,100 · Current $1,365 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: (a) Facility- 2 Wheeling Pittsburgh Drive, Allenport, PA: On or about September 7, 2012, the emergency eye wash stations and showers in the "Alley" and the "Pump House" were not functioning properly. Employees are working with hazardous chemicals such as but not limited to iron oxide, hydrochloric acid, and ferric acid.
Recent events (2)
- — I (S) $1365
- — Z (S) $2100
1910.215 B09
- Issued
- Sep 27, 2012
- Penalty
- Initial $2,100 · Current $1,365 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: (a) Facility- 2 Wheeling Pittsburgh Drive, Allenport, PA: On or about September 7, 2012, an employee was sharpening a chisel on an abrasive wheel that measure one-half inch from the tongue guard.
Recent events (2)
- — I (S) $1365
- — Z (S) $2100
1910.147 C07 IV
- Issued
- Sep 27, 2012
- Abate by
- Oct 19, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training had been accomplished and kept up to date: (a)Facility- 2 Wheeling Pittsburgh Drive, Allenport, PA: On or about September 7, 2012, the employer was not able to provide written certification stating employees were provided with lock out/tag out training.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 L04 III
- Issued
- Sep 27, 2012
- Abate by
- Oct 19, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operators performance was not conducted at least once every 3 years. (a) Facility- 2 Wheeling Pittsburgh Drive, Allenport, PA : On or about September 7, 2012, the employer did not provide refresher training for all employees that operate the Daewoo Forklift.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at American Iron Oxide Company DBA Amrox
View American Iron Oxide Company DBA Amrox's full OSHA safety record →
More inspections in this industry (NAICS 325131)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336197199.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.