Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ACCURATE FELT & GASKET MFG. CO.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ACCURATE FELT & GASKET MFG. CO. in 3239 SOUTH 51ST AVENUE, CICERO, IL 60804 (NAICS 339991). OSHA activity number 336198585.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Accurate Felt & Gasket MFG. CO. — free Get an email when a new federal OSHA severe-injury report for Accurate Felt & Gasket MFG. CO. is published. One employer, no account, unsubscribe in one click.
Site address
3239 SOUTH 51ST AVENUE
City
CICERO
State
IL
ZIP
60804
Mailing
3239 SOUTH 51ST AVENUE, CICERO, IL 60804
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339991
Employees
27
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 1 2 instances 4 exposed
Issued
Dec 6, 2012
Abate by
Jan 25, 2013
Penalty
Initial $1,890 · Current $1,890
29 CFR 1910.147(c)(4)(i):     Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.   55 ton room - On or about October 17, 2012, the written energy control procedures did not include step-by-step lockout procedures for the Walsh No. 1, No. 5 and other part revolution mechanical power presses. Employee(s) were thereby exposed to the hazards associated with an inadvertant startup of equipment.
Recent events (1)
  • — Z (S) $1890

1910.147 C06 II

Serious 1 instance 4 exposed
Issued
Dec 6, 2012
Abate by
Jan 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii):     The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.  55 ton room - On or about October 17, 2012, the employer had not documented through a written certification that periodic inspections had been performed on the energy control procedures.
Recent events (1)
  • — Z (S) $0

1910.212 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 6, 2012
Penalty
Initial $4,410 · Current $4,410
29 CFR 1910.212(a)(1):     Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc.  55 ton room - On or about September 7, 2012, employee(s) were required to hand-feed paper/chipboard into the feed roller of the Sheridan power press. The feed roller on the Sheridan power press was not provided with an adequate guard to protect employee(s) from crushing injuries.
Recent events (1)
  • — Z (S) $4410

1910.217 E01 I

Other-than-serious 2 instances 12 exposed
Issued
Dec 6, 2012
Abate by
Jan 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.217(e)(1)(i):     It shall be the responsibility of the employer to establish and follow a program of periodic and regular inspections of his power presses to ensure that all their parts, auxiliary equipment, and safeguards are in a safe operating condition and adjustment. The employer shall maintain a certification record of inspections which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the power press that was inspected.  55 ton room - On or about October 17, 2012, a program of periodic and regular inspections of the Walsh No. 1, No. 5, and other presses was not developed and followed to ensure that all parts, auxiliary equipment and safeguards were in a safe operating condition and adjustment.
Recent events (1)
  • — Z (O) $0

View Accurate Felt & Gasket MFG. CO.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336198585.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.