Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STAR PIPE SERVICES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STAR PIPE SERVICES, INC. in WYCKOFF 1-11MH WELL, SEC 11-24N-1E, MARLAND, OK 74644 (NAICS 213112). OSHA activity number 336204789.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Star Pipe Services, INC. — free Get an email when a new federal OSHA severe-injury report for Star Pipe Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
WYCKOFF 1-11MH WELL, SEC 11-24N-1E
City
MARLAND
State
OK
ZIP
74644
Mailing
7100 S. BRYANT AVE, OKLAHOMA CITY, OK 73149
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
2
Ownership type
A

6 citations on file for this inspection.

1910.303 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 28, 2012
Abate by
Jan 2, 2013
Penalty
Initial $2,800 · Current $1,700 Reduced
29 CFR 1910.303(b)(2):     Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    East side of the well site:  On or about August 21, 2012, employees inspecting drilling collars and drilling pipe used electric hand tools supplied through a metal receptacle box that was not mounted.  The metal box was intended for fixed, mounted use only.  The box had three knockouts removed allowing access to the box interior.  This exposed the employees to the hazard of electrical shock.
Recent events (2)
  • — I (S) $1700
  • — Z (S) $2800

1910.334 A02 I

Serious Gravity 5 4 instances 2 exposed
Issued
Dec 28, 2012
Abate by
Jan 2, 2013
Penalty
Initial $2,800 · Current $1,700 Reduced
29 CFR 1910.334(a)(2)(i):     Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):    East side of the well site:  On or about August 21, 2012, employees conducting inspection of drilling collars and drilling pipe used electric hand tools that were attached to damaged cord sets.  This exposed the employees to the hazard of electrical shock.
Recent events (2)
  • — I (S) $1700
  • — Z (S) $2800

1910.334 A02 II

Serious Gravity 5 4 instances 2 exposed
Issued
Dec 28, 2012
Abate by
Jan 2, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii):     There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service:    East side of the well site:  On or about August 21, 2012, employees conducting inspection of drilling collars and drilling pipe used electric hand tools that were attached to damaged cord sets.  This exposed the employees to the hazard of electrical shock.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.304 B03 II A

Other-than-serious 1 instance 2 exposed
Issued
Dec 28, 2012
Abate by
Jan 2, 2013
Penalty
Initial $5,600 · Current $0 Reduced
29 CFR 1910.304(b)(3)(ii)(A):     All 125-volt, single-phase, 15-, 20-, and 30-ampere receptacle outlets that were not part of the permanent wiring of the building or structure and that were in use by personnel did not have ground-fault circuit-interrupter protection for personnel:    East end of the well site:  On or about August 21, 2012, employees inspecting drilling collars and pipe used electric hand tools powered from a generator and cord sets and were not provided with ground fault protection.  This exposed the employees to the hazard of electrical shock.      STAR PIPE SERVICES, INC., WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD, 29 CFR 1910.403(b)(3)(ii)(A), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 314932559, CITATION NUMBER1, ITEM NUMBER 2, AND WAS AFFIRMED AS A FINAL ORDER ON June 17, 2011 WITH A FINAL ABATEMENT DATE OF June 17, 2011, WITH RESPECT TO A WORKPLACE HAZARD AT THE GIBSON # 1-28, Sec 28-10N-7E, SEMINOLE CTY.
Recent events (2)
  • — I (O) $0
  • — Z (R) $5600

1910.1200 F05 II

Repeat 4 instances 2 exposed
Issued
Dec 28, 2012
Abate by
Jan 8, 2013
Penalty
Initial $140 · Current $140
29 CFR 1910.1200(f)(5)(ii):     The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings:    East end of the well site:  On or about August 21, 2012, employees inspecting drilling collars and pipe used unmarked containers of kerosene and an asphalt coating to clean and coat the pipe ends.  This exposed the employees to the hazards of fire, inhalation, and skin contact.     STAR PIPE SERVICES, INC., WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD, 29 CFR 1910.1200(f)(5)(ii), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 314932559, CITATION NUMBER 2, ITEM NUMBER 2, AND WAS AFFIRMED AS A FINAL ORDER ON JUNE 17, 2011, WITH A FINAL ABATEMENT DATE OF jUNE 30, 2011, WITH RESPECT TO A WORKPLACE HAZARD AT THE GIBSON #1-28 WELL, SEC 28-10N-7E.
Recent events (2)
  • — I (R) $140
  • — Z (R) $140

1910.1200 F05 I

Other-than-serious 4 instances 2 exposed
Issued
Dec 28, 2012
Abate by
Jan 8, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(i):     The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein:    East end of the well site:  On or about August 21, 2012, employees inspecting drilling collars and pipe used unmarked containers of kerosene and an asphalt coating to clean and coat the pipe ends.  This exposed the employees to the hazards of fire, inhalation, and skin contact.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Star Pipe Services, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336204789.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.