Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: AXION CORPORATION

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of AXION CORPORATION in 317 NICK FITCHEARD ROAD, HUNTSVILLE, AL 35806 (NAICS 336399). OSHA activity number 336235981.

Watch Axion Corporation — free Get an email when a new federal OSHA severe-injury report for Axion Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
AXION CORPORATION
Site address
317 NICK FITCHEARD ROAD
City
HUNTSVILLE
State
AL
ZIP
35806
Mailing
317 NICK FITCHEARD ROAD, HUNTSVILLE, AL 35806
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336399
Employees
11
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Repeat Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4000.00 · Current $4000.00
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:      (a) On or about 9/6/2012 - Machine Shop, a FADAL Computer Numerically Controlled (CNC) machine was not properly guarded in that the guard interlock system was not operable.    Axion Corporation was previously cited for a violation of this occupational safety and health standard(s) or its equivalent standard, 29 CFR 1910.212(a)(1) which was contained in OSHA inspection number 316228956, citation number 01, item number 002, and was affirmed as a final order on July 11, 2012, with respect to a workplace located at 317 Nick Fitcheard Road, Huntsville, Alabama.
Recent events (1)
  • — Z (R) $4000

1910.147 C04 II

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):      (a) On or about 09/06/2012 - Machine Shop, written lockout/tag out procedures did not contain procedural steps to be used for employees performing servicing and maintenance on equipment such as, but not limited to, press brakes, CNC machine, band saws, water jet systems, drill presses, lathes, and shears.
Recent events (1)
  • — Z (O) $0

1910.1200 E01 I

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(e)(1)(i): The written hazard communication program did not include a list of the hazardous chemicals known to be present, using an identity that was referenced on the appropriate material safety data sheet:      (a) On or about 09/06/2012 - Machine Shop, the written hazard communication program did not include a list of hazardous chemicals.
Recent events (1)
  • — Z (O) $0

View AXION CORPORATION's full OSHA safety record →