Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PME OF OHIO, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PME OF OHIO, INC. in 518 W. CRESCENTVILLE RD., CINCINNATI, OH 45246 (NAICS 333613). OSHA activity number 336236591.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch PME of Ohio, INC. — free Get an email when a new federal OSHA severe-injury report for PME of Ohio, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
PME OF OHIO, INC.
Site address
518 W. CRESCENTVILLE RD.
City
CINCINNATI
State
OH
ZIP
45246
Mailing
518 W. CRESCENTVILLE RD., CINCINNATI, OH 45246
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333613
Employees
24
Ownership type
A

6 citations on file for this inspection.

1910.147 D04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 10, 2012
Abate by
Nov 15, 2012
Penalty
Initial $2,380 · Current $1,100 Reduced
29 CFR 1910.147(d)(4)(i):     Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees.    a) On or about September 17, 2012 a lock was not affixed to the electrical disconnect on the DoAll bandsaw by each authorized person when there were more than one employee involved in lockout procedures.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $2380

1910.178 L01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 10, 2012
Abate by
Nov 23, 2012
Penalty
Initial $1,785 · Current $880 Reduced
29 CFR 1910.178(l)(1)(ii):     Prior to permitting an employee to operate a powered industrial truck (except for training purposes), the employer shall ensure that each operator has successfully completed the training required by this paragraph (l), except as permitted by paragraph (l)(5).    a) Employees operating the forklift were not trained to ensure that the operators possessed the knowledge and skills needed to operate a forklift.
Recent events (2)
  • — I (S) $880
  • — Z (S) $1785

1910.212 A01

Serious Gravity 1 1 instance 4 exposed
Issued
Oct 10, 2012
Abate by
Oct 31, 2012
Penalty
Initial $1,785 · Current $880 Reduced
29 CFR 1910.212(a)(1):     Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc.    a) In the lathe department, employee(s) were exposed to the rotating chucks and jaws on the Victor lathes due to no guard in place.
Recent events (2)
  • — I (S) $880
  • — Z (S) $1785

1910.219 C02 I

Other-than-serious 1 instance 2 exposed
Issued
Oct 10, 2012
Penalty
Initial $1,517 · Current $500 Reduced
29 CFR 1910.219(c)(2)(i):     All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires.    a) Guarding was not provided for the drilll that turns the table so the parts could get sprayed, exposing employees to rotating parts.
Recent events (2)
  • — I (O) $500
  • — Z (S) $1517

1910.219 E03 I

Serious Gravity 1 2 instances 2 exposed
Issued
Oct 10, 2012
Penalty
Initial $1,517 · Current $760 Reduced
29 CFR 1910.219(e)(3)(i):     Vertical and inclined belts shall be enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section.    a) Guarding was not provided on the main motor drive belt for the exhaust fan, exposing employees to rotating parts.    b) Guarding was not provided on the main motor drive on the Bridge Part drill press, exposing employees to rotating parts.
Recent events (2)
  • — I (S) $760
  • — Z (S) $1517

1910.147 C06 I

Other-than-serious 1 instance 1 exposed
Issued
Oct 10, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i):     The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.    a) The Company had not conducted periodic inspections of their energy control procedures on at least an annual basis.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View PME of Ohio, INC.'s full OSHA safety record →