LIVERPOOL, NY —
OSHA Inspection: T.J. SHEEHAN DISTRIBUTING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of T.J. SHEEHAN DISTRIBUTING, INC. in 225 COMMERCE BLVD., LIVERPOOL, NY 13088 (NAICS 424810). OSHA activity number 336241195.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- T.J. SHEEHAN DISTRIBUTING, INC.
- Site address
- 225 COMMERCE BLVD.
- City
- LIVERPOOL
- State
- NY
- ZIP
- 13088
- Mailing
- 225 COMMERCE BLVD., LIVERPOOL, NY 13088
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424810
- Employees
- 108
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.101 B
- Issued
- Sep 20, 2012
- Abate by
- Sep 27, 2012
- Penalty
- Initial $2,025 · Current $2,025
General-duty citation text
29 CFR 1910.101(b) Section 3.4.4, Compressed Gas Association Pamphlet P-1-1965, as adopted by 29 CFR 1910.101(b): Compressed gas cylinder(s) were not properly supported to prevent them from being knocked over: a) Pit, Lower Garage area, on or about 9/11/12: Two CO2 cylinders and a Nitrous gas cylinder were not secured to prevent them from being knocked over. b) Dock Area, Door #4, on or about 9/11/12: Three CO2 cylinders were not secured to prevent them from being knocked over. Abatement certification must be submitted for this item.
Recent events (1)
- — Z (S) $2025
1910.37 A04
- Issued
- Sep 20, 2012
- Abate by
- Sep 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times: a) CEW Warehouse, on or about 9/11/12: An emergency light located at the end of stairway was not functioning. Abatement certification must be submitted for this item.
Recent events (1)
- — Z (O) $0
More inspections at T.J. Sheehan Distributing, INC.