Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: L. HOLZNER ELECTRIC COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of L. HOLZNER ELECTRIC COMPANY in CANNON STREET @ BROAD STREET, BRIDGEPORT, CT 06604 (NAICS 238210). OSHA activity number 336255781.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch L. Holzner Electric Company — free Get an email when a new federal OSHA severe-injury report for L. Holzner Electric Company is published. One employer, no account, unsubscribe in one click.
Site address
CANNON STREET @ BROAD STREET
City
BRIDGEPORT
State
CT
ZIP
06604
Mailing
596 JOHN STREET, BRIDGEPORT, CT 06606
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.651 C02

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 12, 2012
Abate by
Sep 17, 2012
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1926.651(c)(2):     A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:      Worksite:  Employees who were working in an excavation that was approximately seven (7) feet deep had not been provided with a ladder or other safe means of egress.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1926.651 K01

Other-than-serious 1 instance 2 exposed
Issued
Sep 12, 2012
Abate by
Sep 17, 2012
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1926.651(k)(1):     An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift:      Worksite:  The employer did not ensure that a trench that was approximately seven feet deep had been inspection by a competent person prior to allowing employees to enter an begin work.
Recent events (2)
  • — I (O) $1400
  • — Z (S) $2000

1926.652 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 12, 2012
Abate by
Sep 17, 2012
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1926.652(a)(1):     Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c).      Worksite:  Employees were working an excavation that was approximately seven (7) feet deep without any form of cave-in protection in place.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

View L. Holzner Electric Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336255781.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.