Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FROST TILE AND MARBLE CO.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of FROST TILE AND MARBLE CO. in 3030 HOUSTON ROAD, NORTON, OH 44203 (NAICS 327122). OSHA activity number 336267380.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Frost Tile and Marble CO. — free Get an email when a new federal OSHA severe-injury report for Frost Tile and Marble CO. is published. One employer, no account, unsubscribe in one click.
Site address
3030 HOUSTON ROAD
City
NORTON
State
OH
ZIP
44203
Mailing
3030 HOUSTON ROAD, NORTON, OH 44203
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327122
Employees
7
Ownership type
A

24 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 8 exposed
Issued
Nov 2, 2012
Abate by
Nov 12, 2012
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:    On or about September 12, 2012, the employer did not guard a storage area that was at a height of approximately 8.5 feet located in the fabrication shop outside of the owner's office.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.23 D01 V

Serious Gravity 5 1 instance 8 exposed
Issued
Nov 2, 2012
Abate by
Nov 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.23(d)(1)(v): On stairways 88 or more inches wide, one handrail on each enclosed side, one stair railing on each open side, and one intermediate stair railing located approximately midway of the width:    On or about September 12, 2012, the employer did not have midrail on either side of the stairs in fabrication area leading to the storage area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 A03

Serious Gravity 5 1 instance 8 exposed
Issued
Nov 2, 2012
Abate by
Nov 7, 2012
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:    On or about September 12, 2012, the employer did not keep exit ways clear from being obstructed. Exit ways near the garage doors were blocked with garabge cans, racks, and tile.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.132 D02

Serious Gravity 5 1 instance 8 exposed
Issued
Nov 2, 2012
Abate by
Dec 31, 2012
Penalty
Initial $2,400 · Current $1,200 Reduced
29 CFR 1910.132(d)(2): The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment:    On or about September 12, 2012, the workplace hazard assessment had not been put in writing and certified with the person conducting the evaluation and the dates the hazard assessment was completed. Employees are working with propane, acetone, and silica. Personal protective equipment has not been identified for these work activities through a written workplace hazard assessment.
Recent events (4)
  • — I $3600
  • — Z $24000
  • — I (S) $1200

1910.132 F01

Serious Gravity 5 1 instance 8 exposed
Issued
Nov 2, 2012
Abate by
Dec 31, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.132(f)(1): The employer did not provide training to each employee who is required by this section to use personal protective equipment:    On or about September 12, 2012, employees required to wear personal protective equipment such as safety glasses and dust masks have not been trained on their use. Employees are working with propane, acetone, and silica.
Recent events (4)
  • — I $0
  • — Z $0
  • — I (S) $0

1910.147 C01

Serious Gravity 5 1 instance 8 exposed
Issued
Nov 2, 2012
Abate by
Feb 28, 2013
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.147(c)(1):  The employer did not establish an energy control program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occurr and cause injury, the machine or equipment would be isolated, and rendered inoperative:    On or about September 12, 2012, the company did not establish a program to protect employees involved with servicing and maintenance of machines and equipment from the unexpected energizing, start up or release of stored energy.  Energy sources included, but are not limited to, electrical, pneumatic, and hydraulic.  The company maintains and services equipment such as, but not limited to, the table saw and polishers.
Recent events (4)
  • — I $2400
  • — Z $16000
  • — I (S) $800

1910.157 E02

Other-than-serious 1 instance 8 exposed
Issued
Nov 2, 2012
Abate by
Jan 31, 2013
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:    On or about Septmber 12, 2012, the employer did not have an ABC fire extinguisher located in the polishing department visually inspected monthly.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1600

1910.157 G02

Other-than-serious 1 instance 8 exposed
Issued
Nov 2, 2012
Abate by
Jan 31, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:    On or about September 12, 2012, the employer did not provide annual training for portable fire extinguishers when available for employee use.
Recent events (4)
  • — I $600
  • — Z $4000
  • — I (O) $0

1910.178 L01 I

Serious Gravity 5 1 instance 8 exposed
Issued
Nov 2, 2012
Abate by
Feb 28, 2013
Penalty
Initial $2,400 · Current $1,200 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    On or about September 12, 2012, the employer had not trained or evaluated employees who drive powered industrial trucks on a daily basis.
Recent events (4)
  • — I $3600
  • — Z $24000
  • — I (S) $1200

1910.178 Q07

Serious Gravity 5 1 instance 8 exposed
Issued
Nov 2, 2012
Abate by
Feb 28, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service:    On or about September 12, 2012, the employer did not examine forktrucks on a daily basis before they were put into service.
Recent events (4)
  • — I $0
  • — Z $0
  • — I (S) $0

1910.212 A03 II

Serious Gravity 10 1 instance 8 exposed
Issued
Nov 2, 2012
Abate by
Dec 31, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.212(a)(3)(ii): The  point of operation of machines whose operation exposed an employee to injury, was not guarded:    On or about September 12, 2012, the table saw in the facbiraction area used to cut granite was not properly guarded. Employees were exposed to the rotating blade when operating the saw.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.303 E

Serious Gravity 1 1 instance 8 exposed
Issued
Nov 2, 2012
Abate by
Dec 31, 2012
Penalty
Initial $1,200 · Current $2,000
29 CFR 1910.303(e): Markings were not provided on electrical equipment giving voltage, current, wattage, and other ratings as necessary:    On or about September 12, 2012, the employer did not mark the distribution panel located in the polishing department with the voltage and other ratings.
Recent events (4)
  • — I $1800
  • — Z $12000
  • — I (S) $2000

1910.304 G05

Serious Gravity 5 1 instance 8 exposed
Issued
Nov 2, 2012
Abate by
Dec 31, 2012
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    On or about September 12, 2012, the employer did not have a electrical outlet circuit continuous. The electrical outlet showed reveresed polarity in the wet polishing department.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1910.305 E02

Serious Gravity 5 1 instance 8 exposed
Issued
Nov 2, 2012
Abate by
Dec 31, 2012
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1910.305(e)(2): Switches, circuit breakers and switchboards installed in wet locations were not enclosed in weatherproof enclosures:    On or about September 12, 2012, the employer had circuit breakers installed in a wet location and they were not enclosed in weatherproof enclosure.
Recent events (4)
  • — I $0
  • — Z $0
  • — I (S) $0

1910.305 G01 I

Serious Gravity 5 1 instance 8 exposed
Issued
Nov 2, 2012
Abate by
Dec 31, 2012
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1910.305(g)(1)(i): Electrical cords and cables were not approved for conditions of use and location:    On or about September 12, 2012, the employer provided electrical cords that were not suitable for the wet conditions in the wet polishing area. Small power tools were being powered by electrical cords that were not suitable for wet areas.
Recent events (4)
  • — I $0
  • — Z $0
  • — I (S) $0

1910.334 A04

Serious Gravity 5 1 instance 8 exposed
Issued
Nov 2, 2012
Abate by
Jan 6, 2014
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1910.334(a)(4): Portable electric equipment and flexible cords were used in highly conductive work locations (such a those inundated with water or other conductive liquids), and in job locations where employees are likely to contact water or conductive liquids, should be approved for those locations:    On or about September 12, 2012, the employer had electrical boxes that were not GFCI protected and were being used in wet locations.
Recent events (4)
  • — I $0
  • — Z $0
  • — I (S) $0

1910.1000 C

Serious Gravity 10 1 instance 8 exposed
Issued
Nov 2, 2012
Abate by
Feb 28, 2013
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.1000(c): An employee was exposed to respirable dust containing crystalline silica in excess of the 8-hour time weighted average limits of (0.93 mg/m3) listed in Table Z-3:    On or about September 18, 2012, the fabricator working in the granite shop was exposed to respirable dust containing crystalline silica at 5.08 mg/m3 which is approximately 5.49 times the permissable exposure limit (PEL) of 0.93 mg/m3; exposure calculations included a zero increment for 210 minutes not sampled. At this time employees are being exposed to levels above the PEL.
Recent events (4)
  • — I $4200
  • — Z $28000
  • — I (S) $1400

1910.1000 E

Serious Gravity 10 1 instance 8 exposed
Issued
Nov 2, 2012
Abate by
Feb 28, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d):    For the employee including, but not limited to, the employee whose exposure is described in Citation 1, Item 14(a).     On or about September 18, 2012, the fabricator working in the granite shop was exposed to respirable dust containing crystalline silica at 5.08 mg/m3 which is approximately 5.49 times the permissable exposure limit (PEL) of 0.93 mg/m3; exposure calculations included a zero increment for 210 minutes not sampled. At this time employees are being exposed to levels above the PEL and the employer shall require mandatory use of a respirator until feasible engineering controls can be put in place.    General methods of control include, but are not limited to:    1. Install a dust control appratus on the portable grinder.    2. Use an exhaust ventilation system to capture silica dust.
Recent events (4)
  • — I $0
  • — Z $0
  • — I (S) $0

1910.134 C01

Serious Gravity 5 1 instance 8 exposed
Issued
Nov 2, 2012
Abate by
Feb 28, 2013
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1910.134(c)(1): The employer did not ensure that a written respiratory protection program with worksite-specific procedures was established and implemented to include the provisions of (i)-(ix), as applicable:    On or about September 18, 2012, the fabricator working in the granite shop was exposed to respirable dust containing crystalline silica dust at 5.08 mg/m3 which is appoximately 5.49 times the permissable exposure limit (PEL) of 0.93 mg/m3; exposure calculations included a zero increment for 210 minutes not sampled. At this time employees are being exposed to levels above the PEL and the employer shall require mandatory use of a respirator until feasible engineering controls can be put in place.
Recent events (4)
  • — I $0
  • — Z $0
  • — I (S) $0

1910.1200 E01

Serious Gravity 5 1 instance 8 exposed
Issued
Nov 2, 2012
Abate by
Dec 31, 2012
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.1200(e)(1):  The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    On or about September 12, 2012, the company did not implement and maintain a written hazard communication program at the site. Employees work with hazardous materials such as, but not limited to propane, acetone, and silica.
Recent events (4)
  • — I $3000
  • — Z $20000
  • — I (S) $1000

1910.1200 H01

Serious Gravity 5 1 instance 8 exposed
Issued
Nov 2, 2012
Abate by
Dec 31, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:    On or about September 12, 2012, the employer did not provide training or information to employees working with hazardous chemicals such as, but not limited to propane, acetone, and silica.
Recent events (4)
  • — I $0
  • — Z $0
  • — I (S) $0

1910.22 D01

Other-than-serious 1 instance 8 exposed
Issued
Nov 2, 2012
Abate by
Nov 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(1): In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purposes, the loads approved by the building official were not marked in a conspicuous place in each space to which they related:    On or about September 12, 2012, the employer did not load rate the overhead storage area in granite warehouse/fabrication area.
Recent events (4)
  • — I $600
  • — Z $4000
  • — I (O) $0

1910.303 B07 I

Other-than-serious 1 instance 8 exposed
Issued
Nov 2, 2012
Abate by
Nov 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment:    On or about September 12, 2012, the employer had a knockout missing on a electrical box near the polishing department.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01 I

Other-than-serious 1 instance 8 exposed
Issued
Nov 2, 2012
Abate by
Nov 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(i): Work space was less than 30 inches wide in front of electric equipment operating at 600 volts, nominal, or less:    On or about September 12, 2012, the employer had electrical panels blocked by pallets of tile and granite near the garage doors.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Frost Tile and Marble CO.'s full OSHA safety record →