LOGAN, WV —
OSHA Inspection: COCA-COLA BOTTLING COMPANY CONSOLIDATED
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of COCA-COLA BOTTLING COMPANY CONSOLIDATED in WHITMAN ROAD, LOGAN, WV 25601 (NAICS 312111). OSHA activity number 336273388.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COCA-COLA BOTTLING COMPANY CONSOLIDATED
- Site address
- WHITMAN ROAD
- City
- LOGAN
- State
- WV
- ZIP
- 25601
- Mailing
- P.O. BOX 360, LOGAN, WV 25601
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 312111
- Employees
- 26
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.23 E01
- Issued
- Dec 19, 2012
- Penalty
- Initial $3,400 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.23(e)(1): Standard railing(s) did not consist of top rail, intermediate rail and/or posts and/or did not have a vertical height of 42 inches (106.7 cm) nominal from upper surface of top rail to floor, platform runway, or ramp level: (a)Mezzanine Level: Employees were exposed to a 9 foot fall hazard from the mezzanine level to ground level. The chain standard railing consisted of a top rail at 27 inches and an intermediate rail at 15 inches, as determined on September 11, 2012.
Recent events (2)
- — I (S) $3000
- — Z (S) $3400
1910.303 F02
- Issued
- Dec 19, 2012
- Penalty
- Initial $2,550 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: (a)Warehouse: A Federal Pacific Electric Company breaker disconnect box (Box #1) that housed the breakers for the lighting and wall receptacles was not labeled to indicate the purpose for the disconnecting means, as determined on September 11, 2012.
Recent events (2)
- — I (O) $0
- — Z (S) $2550
1910.305 G02 III
- Issued
- Dec 19, 2012
- Penalty
- Initial $2,550 · Current $2,150 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: (a)Warehouse: Employees plug and unplug a Pro Standard portable pedestal fan that had the outer insulation of the power cord separated from the plug connection. Insulated energized conductors were exposed due to the separation, as determined on September 11, 2012.
Recent events (2)
- — I (S) $2150
- — Z (S) $2550
1910.305 G01 IV D
- Issued
- Dec 19, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were attached to building surfaces: (a) Mechanic Garage: Approximately 10 feet of an extension cord was attached to the garage wall with screw in attachments to provide power for a computer, printer and radio, as determined on September 11, 2012.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 F06 I
- Issued
- Dec 19, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(6)(i): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(v) (a) Outside Warehouse Office: Three clear spray bottles containing a mixture of water and Windex, used by sales employees to clean glass surfaces in the field, were not labeled with the identity of the contents and appropriate hazard warnings, as determined on September 11, 2012.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Coca-Cola Bottling Company Consolidated
View Coca-Cola Bottling Company Consolidated's full OSHA safety record →
More inspections in this industry (NAICS 312111)
More inspections in WV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336273388.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.