OSHKOSH, WI —
OSHA Inspection: R B ROOFING & SIDING
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of R B ROOFING & SIDING in 1169 SUNKIST RD., OSHKOSH, WI 54906 (NAICS 238160). OSHA activity number 336290994.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- R B ROOFING & SIDING
- Site address
- 1169 SUNKIST RD.
- City
- OSHKOSH
- State
- WI
- ZIP
- 54906
- Mailing
- 741 W. 17TH AVE, OSHKOSH, WI 54902
What kind of inspection was it?
- Inspection type
- Programmed Related (J)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 10
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.1053 B01
- Issued
- Dec 13, 2012
- Abate by
- Jan 14, 2013
- Penalty
- Initial $2,800 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) The ladder used to access the roof of the house did not extend three feet above the roof edge.
Recent events (2)
- — I (S) $1000
- — Z (S) $2800
1926.1053 B04
- Issued
- Dec 13, 2012
- Abate by
- Jan 10, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) The top half of a fiberglass extension ladder was used as a separate piece to access the roof of the house.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B20
- Issued
- Dec 13, 2012
- Abate by
- Jan 10, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(20): Employees did not face the ladder when ascending or descending the ladder: a) One employee climbed down the ladder from the roof while facing away from the ladder twice, while he knew the compliance officer was watching.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B21
- Issued
- Dec 13, 2012
- Abate by
- Jan 10, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(21): Each employee was not grasping the ladder with at least one hand when progressing up and/or down the ladder: a) An employee twice climbed down a ladder, without holding on while facing away from the ladder and carrying roofing material.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.102 A01
- Issued
- Dec 13, 2012
- Abate by
- Jan 10, 2013
- Penalty
- Initial $4,000 · Current $0 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. a) Employees performing residential re-roofing work were not provided with or wearing safety glasses. R.B. Roofing and Siding was previously cited for a violation of this Occupational Safety and Health Standard which was contained in OSHA Inspection #312558133, Citation #1, Item #1, which was affirmed as a Final Order on 11/16/2010, with respect to a workplace located at 1908 N. Linwood, Appleton, WI 54914.
Recent events (2)
- — I (R) $0
- — Z (R) $4000
1926.501 B13
- Issued
- Dec 13, 2012
- Abate by
- Jan 14, 2013
- Penalty
- Initial $4,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b) a) Employees performing residential re-roofing work were not using any form of fall protection. R.B. Roofing and Siding was previously cited for a violation of this Occupational Safety and Health Standard which was contained in OSHA Inspection #312558133, Citation #1, Item #2A, which was affirmed as a Final Order on 11/16/2010, with respect to a workplace located at 1908 N. Linwood, Appleton, WI 54914.
Recent events (2)
- — I (R) $1000
- — Z (R) $4000
More inspections at R B Roofing & Siding
View R B Roofing & Siding's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336290994.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.